atmInterfaceMaxActiveVpiBits
ATM-MIB ·
.1.3.6.1.2.1.37.1.2.1.5
Object
column r/w
Integer32
The maximum number of active VPI bits configured for use at the ATM interface. At the ATM UNI, the maximum number of active VPI bits configured for use ranges from 0 to 8 only.
Context
- MIB
- ATM-MIB
- OID
.1.3.6.1.2.1.37.1.2.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- atmInterfaceConfEntry
- Groups
- 2
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ATM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATM-MIB::atmInterfaceMaxActiveVpiBits'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ATM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ATM-MIB::atmInterfaceMaxActiveVpiBits.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ATM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ATM-MIB::atmInterfaceMaxActiveVpiBits'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-12
Conformance
Member of
Compliance refinements
atmMIBCompliance
readonly
Write access is not required.
atmMIBCompliance2
readonly
Write access is not required.
At the ATM UNI the maximum number of
active VPI bits configured for use ranges
from 0 to 8 only.
Implementations may support smaller ranges.
At the ATM UNI the maximum number of
active VPI bits configured for use ranges
from 0 to 8 only.
Implementations may support smaller ranges.