WLSX-POE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
19
.1.3.6.1.4.1.14823.2.2.1.18.1.1 · 1 row entry · 14 columns
A table of objects that display the parameters configured
for a power ethernet port.
wlsxPsePortEntry entry .1.3.6.1.4.1.14823.2.2.1.18.1.1.1
A set of objects that display the configuration of a power
ethernet port.
Indexes
wlsxPsePortIndex
Column Syntax OID
wlsxPsePortIndex
This variable uniquely identifies the power
ethernet port for which this entry
is populated.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.1
wlsxPsePortAdminStatus
Admin status of a power ethernet port.

A value of enable(1) means that the port
has PSE functions enabled on it.

A value of disable(2) means that the port
does not support or has disabled P…
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.2
wlsxPsePortState
This object indicates the status of the port.
The reason for these states is indicated by wlsxPsePortStatus.

on(1) - indicates that PSE is sourcing power.
off(2) - indicates that PSE is not sourcing powe…
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.3
wlsxPsePortStatus
This object indicates the status of the port.

unknown(1) - indicates either a state of off with the
reason being not known or the state is
on.…
Enumeration
Enumerated Values:
1unknown
2offAdmin
3offPowerManagement
4offIllegalClass
5offDetectionProgress
6offHardwareError
7offNonStandardPd
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.4
wlsxPsePortDiscoveryMode
This object indicates the method of discovery used
by the system for the detection of the Powered Device(PD).

A value of unknown(0) means that the discovery method
is unknown on this port.
Enumeration
Enumerated Values:
0unknown
1off
2ieee
3cisco
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.5
wlsxPsePortIsPdDetected
This object indicates if a Powered Device(PD) is
detected on this port.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.6
wlsxPsePortIsIeeePd
This object indicates the IEEE compliance of a
Powered Device(PD).

A value of true(1) means the Powered Device(PD)
is IEEE compliant.

A value of false(2) means the Powered Device is
not IEE…
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.7
wlsxPsePortPdClass
This object indicates the Power classification of the
Powered Device(PD) connected on the port.

A value of 'class0(1)' indicates that the power
classification of the powered device falls into
class 0 in…
Enumeration
Enumerated Values:
0unknownClass
1class0
2class1
3class2
4class3
5class4
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.8
wlsxPsePortPriority
This object indicates the configured priority for this port.

low(1) - indicates the priority of the port is low.
high(2) - indicates the priority of the port is high.
critical(3) - indicates the …
Enumeration
Enumerated Values:
1low
2high
3critical
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.9
wlsxPsePortDefaultPowerMax
This object indicates the default maximum power available
on this port.
milliwattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.10
wlsxPsePortPowerAllocated
This object indicates the configured power allocation
on this port.
milliwattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.11
wlsxPsePortPowerConsumed
This object gives the power consumption by the PD on this port.
milliwattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.12
wlsxPsePortVoltage
This object indicates the voltage on this port.
milliVoltsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.13
wlsxPsePortCurrent
This object indicates the current on this port.
milliAmpsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.1.1.14
.1.3.6.1.4.1.14823.2.2.1.18.1.2 · 1 row entry · 5 columns
A table of objects that display all the details about the 
Power Sourcing Equipment(PSE).
wlsxPseSlotEntry entry .1.3.6.1.4.1.14823.2.2.1.18.1.2.1
A set of objects that displays all the information about
the PSE on this device on a per slot basis.
Indexes
wlsxPseSlotIndex
Column Syntax OID
wlsxPseSlotIndex
This object uniquely identifies a PSE entry.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.2.1.1
wlsxPseSlotPowerAvailable
This object indicates the total amount of power
available from this PSE.
wattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.2.1.2
wlsxPseSlotPowerConsumption
This object indicates the total amount of power consumed
from this PSE.
wattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.2.1.3
wlsxPseSlotGuardBand
This object indicates the power left unused to be provided
in case of spikes in the amount of power used.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.14823.2.2.1.18.1.2.1.4
wlsxPseSlotPoEManagementMode
This object indicates the PSE management mode.

A value of dynamic(1) indicates that it is
dynamic power management.

A value of static(2) indicates that it is
static power management.
Enumeration
Enumerated Values:
1dynamic
2static
3class
.1.3.6.1.4.1.14823.2.2.1.18.1.2.1.5