SCTE-HMS-HE-OPTICAL-SWITCH-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
16
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1 · 1 row entry · 9 columns
A table containing information about Optical Switch used
in an indoor environment.
heOpSwitchUnitEntry entry .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1
List of information about each optical switch.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
heOpSwitchMode
This controls and/or reports the switching mode. If
automatic(1), the optical switch will evaluate the optical
input status and make the decision to affect the switch state.
If set to manual(2), the optical switch …
Enumerationr/w
Enumerated Values:
1automatic
2manual
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.1
heOpSwitchControl
Sets the intended state of the Optical Switch. The effect
of this control will depend on the value of heOpSwitchMode.
If heOpSwitchMode is set to automatic, the value this
control is set to will be the preferred setti…
Enumerationr/w
Enumerated Values:
1pathA
2pathB
3cross
4bar
5bothA
6bothB
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.2
heOpSwitchRevertEnable
This controls the use of revertive switching.

If set to on, the switch will attempt to go back to the
preferred settings indicated by heOpSwitchControl if
heOpSwitchMode is set to automatic, and the i…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl Enumeration
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.3
heOpSwitchState
Reports the state of the Optical Switch. Not all enumerations
must be supported. For example, an A-B optical switch may
support only the pathA and pathB enumerations while a
cross-bar switch may support cross, bar,…
Enumeration
Enumerated Values:
1pathA
2pathB
3cross
4bar
5bothA
6bothB
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.4
heOpSwitchFailoverStatus
The integral status of both inputs.

A value is fault(2), if current switch state heOpSwitchState
is different than the preferred setting heOpSwitchControl,
otherwise, it is normal(1).
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus Enumeration
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.5
heOpSwitchBothInputStatus
The integral status of both inputs.

A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).

This object must provide for the alarm management cap…
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus Enumeration
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.6
heOpSwitchSelectWavelength
Wavelength feeding the particular input of the optical switch.
Typical values might be 131000 (1310 nm) and 155000 (1550 nm).
0.01 nmSCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeterr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter Unsigned32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.7
heOpSwitchHysteresis
Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor.
0.1 dBInteger32r/w
Constraints:
range: -20-20
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.8
heOpSwitchWaitToRestoreTime
Controls hysteresis time in sec.

If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time specified by this object.
1 secSNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.9
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2 · 1 row entry · 5 columns
A table containing information about each Optical Switch 
input used in an indoor environment.
heOpSwitchInputEntry entry .1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1
List of information about each optical switch input.
Indexes
ENTITY-MIBentPhysicalIndex heOpSwitchInputIndex
Column Syntax OID
heOpSwitchInputIndex
Index number corresponding to the Optical Input.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.1
heOpSwitchInputOpticalLevel
The measured optical input power for the optical switch.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthdBm Integer32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.2
heOpSwitchSetInputPowerThreshold
Input power switchover point for this input.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBmr/w
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeTenthdBm Integer32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.3
heOpSwitchInputStatus
The integral status of the input.

A value is fault(2), if the input levels are not in
the nominal range; otherwise, it is normal(1).

This object must provide for the alarm management capab…
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Textual Convention: SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus Enumeration
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.4
heOpSwitchInputDescription
A description of the switch input. The description text is
to be determined by the equipment manufacturer. For example,
Input A or Side B.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.5
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3 · 1 row entry · 2 columns
A table containing information about each Optical Switch 
output used in an indoor environment.
heOpSwitchOutputEntry entry .1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1
List of information about each optical switch output.
Indexes
ENTITY-MIBentPhysicalIndex heOpSwitchOutputIndex
Column Syntax OID
heOpSwitchOutputIndex
Index number corresponding to the Optical Output.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1.1
heOpSwitchOutputDescription
A description of the switch output. The description text is
to be determined by the equipment manufacturer. For example,
Output A or Secondary Output.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1.2