SCTE-HMS-HE-OPTICAL-SWITCH-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
16
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1 · 1 row entry · 9 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpSwitchUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB::heOpSwitchUnitTable'
A table containing information about Optical Switch used
in an indoor environment.
heOpSwitchUnitEntry row .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1
List of information about each optical switch.
Column Syntax OID
This controls and/or reports the switching mode. If
automatic(1), the optical switch will evaluate the optical
input status and make the decision to affect the switch state.
If set to manual(2), the optical switch …
Enumerationr/w
Enumerated Values:
1automatic
2manual
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.1
Sets the intended state of the Optical Switch. The effect
of this control will depend on the value of heOpSwitchMode.
If heOpSwitchMode is set to automatic, the value this
control is set to will be the preferred setti…
Enumerationr/w
Enumerated Values:
1pathA
2pathB
3cross
4bar
5bothA
6bothB
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.2
This controls the use of revertive switching.

If set to on, the switch will attempt to go back to the
preferred settings indicated by heOpSwitchControl if
heOpSwitchMode is set to automatic, and the i…
SCTE-HMS-HEADENDIDENT-MIBHeOnOffControlr/w
Type Values:
1off
2on
3meaningless
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.3
Reports the state of the Optical Switch. Not all enumerations
must be supported. For example, an A-B optical switch may
support only the pathA and pathB enumerations while a
cross-bar switch may support cross, bar,…
Enumeration
Enumerated Values:
1pathA
2pathB
3cross
4bar
5bothA
6bothB
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.4
The integral status of both inputs.

A value is fault(2), if current switch state heOpSwitchState
is different than the preferred setting heOpSwitchControl,
otherwise, it is normal(1).
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.5
The integral status of both inputs.

A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).

This object must provide for the alarm management cap…
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.6
Wavelength feeding the particular input of the optical switch.
Typical values might be 131000 (1310 nm) and 155000 (1550 nm).
0.01 nmSCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeterr/w .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.7
Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor.
0.1 dBInteger32r/w
Constraints:
range: -20-20
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.8
Controls hysteresis time in sec.

If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time specified by this object.
1 secSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.9
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2 · 1 row entry · 5 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpSwitchInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB::heOpSwitchInputTable'
A table containing information about each Optical Switch 
input used in an indoor environment.
heOpSwitchInputEntry row .1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1
List of information about each optical switch input.
Column Syntax OID
Index number corresponding to the Optical Input.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.1
The measured optical input power for the optical switch.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBm .1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.2
Input power switchover point for this input.
0.1 dBmSCTE-HMS-HEADENDIDENT-MIBHeTenthdBmr/w .1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.3
The integral status of the input.

A value is fault(2), if the input levels are not in
the nominal range; otherwise, it is normal(1).

This object must provide for the alarm management capab…
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
Type Values:
1normal
2fault
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.4
A description of the switch input. The description text is
to be determined by the equipment manufacturer. For example,
Input A or Side B.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.5
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3 · 1 row entry · 2 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heOpSwitchOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-OPTICAL-SWITCH-MIB::heOpSwitchOutputTable'
A table containing information about each Optical Switch 
output used in an indoor environment.
heOpSwitchOutputEntry row .1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1
List of information about each optical switch output.
Column Syntax OID
Index number corresponding to the Optical Output.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1.1
A description of the switch output. The description text is
to be determined by the equipment manufacturer. For example,
Output A or Secondary Output.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.5591.1.11.1.4.1.1.3.1.2