heOpSwitchFailoverStatus
SCTE-HMS-HE-OPTICAL-SWITCH-MIB ·
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.5
Object
column
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
The integral status of both inputs.
A value is fault(2), if current switch state heOpSwitchState
is different than the preferred setting heOpSwitchControl,
otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent.
Context
- MIB
- SCTE-HMS-HE-OPTICAL-SWITCH-MIB
- OID
.1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- heOpSwitchUnitEntry
- Table
- heOpSwitchUnitTable
- Siblings
- 8
Syntax
SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
- Source
- SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | normal |
2 | fault |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| heOpSwitchMode This controls and/or reports the switching mode. If
automatic(1), the optical switch will evaluate the optical
input status and make the decision to affect the switch state.
… | column | Enumeration | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.1 |
| heOpSwitchControl Sets the intended state of the Optical Switch. The effect
of this control will depend on the value of heOpSwitchMode.
If heOpSwitchMode is set to automatic, the value this
contr… | column | Enumeration | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.2 |
| heOpSwitchRevertEnable This controls the use of revertive switching.
If set to on, the switch will attempt to go back to the
preferred settings indicated by heOpSwitchControl if
heOpS… | column | SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.3 |
| heOpSwitchState Reports the state of the Optical Switch. Not all enumerations
must be supported. For example, an A-B optical switch may
support only the pathA and pathB enumerations while a
… | column | Enumeration | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.4 |
| heOpSwitchBothInputStatus The integral status of both inputs.
A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).
This object m… | column | SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.6 |
| heOpSwitchSelectWavelength Wavelength feeding the particular input of the optical switch.
Typical values might be 131000 (1310 nm) and 155000 (1550 nm). | column | 0.01 nm SCTE-HMS-HEADENDIDENT-MIBHeHundredthNanoMeter | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.7 |
| heOpSwitchHysteresis Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor. | column | 0.1 dB Integer32 | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.8 |
| heOpSwitchWaitToRestoreTime Controls hysteresis time in sec.
If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time sp… | column | 1 sec SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5591.1.11.1.4.1.1.1.1.9 |