Finisher-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
4
Rows
4
Columns
38
finDeviceTable
table.1.3.6.1.2.1.43.30.1
·
1 row entry
·
10 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk finDeviceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Finisher-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Finisher-MIB::finDeviceTable'
This table defines the finishing device subunits, including information regarding possible configuration options and the status for each finisher device subunit.
There is an entry in the finishing device table for each
possible finisher process. Each individual finisher process is
implemented by a finishing device represented in this table.
possible finisher process. Each individual finisher process is
implemented by a finishing device represented in this table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value used to identify a finisher process.
Although these values may change due to a major reconfiguration of the printer system (e.g., the addition of new finishing processes), the values are normally expected… |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.2.1.43.30.1.1.1 |
||||||||||||||||||||||||||||||||||||
|
Defines the type of finishing process associated with this
table row entry. |
IANA-FINISHER-MIBFinDeviceTypeTC Type Values:
|
.1.3.6.1.2.1.43.30.1.1.2 |
||||||||||||||||||||||||||||||||||||
|
Indicates if this finishing device subunit is available
and whether the device subunit is enabled. |
Printer-MIBPresentOnOffr/w Type Values:
|
.1.3.6.1.2.1.43.30.1.1.3 |
||||||||||||||||||||||||||||||||||||
|
The unit of measure for specifying the capacity of this
finisher device subunit. |
Printer-MIBPrtCapacityUnitTC Type Values:
|
.1.3.6.1.2.1.43.30.1.1.4 |
||||||||||||||||||||||||||||||||||||
|
The maximum capacity of this finisher device subunit in
finDeviceCapacityUnits. If the device can reliably sense this value, the value is sensed by the finisher device and is read-only: otherwise the val… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.30.1.1.5 |
||||||||||||||||||||||||||||||||||||
|
The current capacity of this finisher device subunit in
finDeviceCapacityUnits. If the device can reliably sense this value, the value is sensed by the finisher and is read-only: otherwise the value may be written by a… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.30.1.1.6 |
||||||||||||||||||||||||||||||||||||
|
Indicates the media paths which can supply media for this
finisher device. The value of this object is a bit map in an octet string with each position representing the value of a prtMediaPathIndex. For a media path th… |
OctetString Constraints: range: 1-63 |
.1.3.6.1.2.1.43.30.1.1.7 |
||||||||||||||||||||||||||||||||||||
|
Indicates the printer output subunits this finisher device
subunit services. The value of this object is a bit map in an octet string with each position representing the value of a prtOutputIndex. For a… |
OctetString Constraints: range: 1-63 |
.1.3.6.1.2.1.43.30.1.1.8 |
||||||||||||||||||||||||||||||||||||
|
Indicates the current status of this finisher device
subunit. |
Printer-MIBPrtSubUnitStatusTC Type Constraints: range: 0..126 |
.1.3.6.1.2.1.43.30.1.1.9 |
||||||||||||||||||||||||||||||||||||
|
A free form text description of this device subunit in the
localization specified by prtGeneralCurrentLocalization. |
Printer-MIBPrtLocalizedDescriptionStringTC Type Constraints: range: 0..255 |
.1.3.6.1.2.1.43.30.1.1.10 |
finSupplyTable
table.1.3.6.1.2.1.43.31.1
·
1 row entry
·
9 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk finSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Finisher-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Finisher-MIB::finSupplyTable'
Each unique source of supply is an entry in the finisher
supply table. Each supply entry has its own
characteristics associated with it such as colorant and
current supply level.
A list of finisher devices, with their associated
supplies and supplies characteristics.
supplies and supplies characteristics.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value used by a finisher to identify this supply
container/receptacle. Although these values may change due to a major reconfiguration of the finisher (e.g., the addition of new supply sources to the finisher)… |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.2.1.43.31.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The value of finDeviceIndex corresponding to the finishing
device subunit with which this finisher supply is associated. The value zero indicates the associated finishing device is Unknown. |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.2.1.43.31.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
This value indicates whether this supply entity
represents a supply that is consumed or a container that is filled. |
Printer-MIBPrtMarkerSuppliesClassTC Type Values:
|
.1.3.6.1.2.1.43.31.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The type of this supply.
|
IANA-PRINTER-MIBPrtMarkerSuppliesTypeTC Type Values:
|
.1.3.6.1.2.1.43.31.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The description of this supply/receptacle in text useful
for operators and management applications and in the localization specified by prtGeneralCurrentLocalization. |
Printer-MIBPrtLocalizedDescriptionStringTC Type Constraints: range: 0..255 |
.1.3.6.1.2.1.43.31.1.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Unit of measure of this finisher supply container or
receptacle. |
Printer-MIBPrtMarkerSuppliesSupplyUnitTC Type Values:
|
.1.3.6.1.2.1.43.31.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The maximum capacity of this supply container/receptacle
expressed in Supply Units. If this supply container/ receptacle can reliably sense this value, the value is sensed and is read-only; otherwise the value may be … |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.31.1.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed and is read-only; otherwise the… |
Integer32r/w Constraints: range: -3-2147483647 |
.1.3.6.1.2.1.43.31.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The name of the color associated with this supply.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.2.1.43.31.1.1.9 |
finSupplyMediaInputTable
table.1.3.6.1.2.1.43.32.1
·
1 row entry
·
15 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk finSupplyMediaInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Finisher-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Finisher-MIB::finSupplyMediaInputTable'
The input subunits associated with a finisher supply media are each represented by an entry in this table.
A list of finisher supply media input subunit features and
characteristics.
characteristics.
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value used by a finisher to identify this supply
media input subunit. Although these values may change due to a major reconfiguration of the finisher (e.g., the addition of new supply media input sources to th… |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.2.1.43.32.1.1.1 |
||||||||||||||||
|
The value of finDeviceIndex corresponding to the finishing
device subunit with which this finisher media supply is associated. The value zero indicates the associated device is unknown. |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.2.1.43.32.1.1.2 |
||||||||||||||||
|
The value of finSupplyIndex corresponding to the finishing
supply subunit with which this finisher media supply is associated. The value zero indicates the associated finishing supply is unknown or there is no applicab… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.2.1.43.32.1.1.3 |
||||||||||||||||
|
The type of technology (discriminated primarily according
to the feeder mechanism type) employed by the input subunit. |
IANA-PRINTER-MIBPrtInputTypeTC Type Values:
|
.1.3.6.1.2.1.43.32.1.1.4 |
||||||||||||||||
|
The unit of measure for specifying dimensional values for
this input device. |
Printer-MIBPrtMediaUnitTC Type Values:
|
.1.3.6.1.2.1.43.32.1.1.5 |
||||||||||||||||
|
This object provides the value of the dimension in the
feed direction of the media that is placed or will be placed in this input device. Feed dimension measurements are taken parallel to the feed direction of the devi… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.32.1.1.6 |
||||||||||||||||
|
This object provides the value of the dimension across the
feed direction of the media that is placed or will be placed in this input device. The cross feed direction is ninety degrees relative to the feed direction on… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.32.1.1.7 |
||||||||||||||||
|
This value indicates the current status of this input
device. |
Printer-MIBPrtSubUnitStatusTC Type Constraints: range: 0..126 |
.1.3.6.1.2.1.43.32.1.1.8 |
||||||||||||||||
|
The name of the current media contained in this input
device. Examples are Engineering Manual Cover, Section A Tab Divider or any ISO standard names. |
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.2.1.43.32.1.1.9 |
||||||||||||||||
|
The name assigned to this input subunit.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.2.1.43.32.1.1.10 |
||||||||||||||||
|
A free form text description of this input subunit in the
localization specified by prtGeneralCurrentLocalization. |
Printer-MIBPrtLocalizedDescriptionStringTC Type Constraints: range: 0..255 |
.1.3.6.1.2.1.43.32.1.1.11 |
||||||||||||||||
|
Indicates if this subunit has some security associated
with it. |
Printer-MIBPresentOnOffr/w Type Values:
|
.1.3.6.1.2.1.43.32.1.1.12 |
||||||||||||||||
|
The weight of the media associated with this Input device
in grams per meter squared. The value (-1) means other and specifically indicates that the device places no restriction on this parameter. The value (-2) means… |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.2.1.43.32.1.1.13 |
||||||||||||||||
|
This object identifies the thickness of the input media
processed by this document input subunit measured in micrometers. This value may be used by devices (or operators) to set up proper machine tolerances for the fee… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.32.1.1.14 |
||||||||||||||||
|
The name of the type of medium associated with this input
subunit. |
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.2.1.43.32.1.1.15 |
finDeviceAttributeTable
table.1.3.6.1.2.1.43.33.1
·
1 row entry
·
4 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk finDeviceAttributeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Finisher-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Finisher-MIB::finDeviceAttributeTable'
The attribute table defines special parameters that are applicable only to a minority of the finisher devices. An attribute table entry is used, rather than unique objects, to minimize the number of MIB objects and to allow for expansion without the addition of MIB objects. Each finisher device is represented by a separate row in the device subunit attribute table.
Each entry defines a finisher function parameter that
cannot be represented by an object in the finisher
device subunit table.
cannot be represented by an object in the finisher
device subunit table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Defines the attribute type represented by this row.
|
IANA-FINISHER-MIBFinAttributeTypeTC Type Values:
|
.1.3.6.1.2.1.43.33.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
An index that allows the discrimination of an attribute
instance when the same attribute occurs multiple times for a specific instance of a finisher function. The value of this index shall be 1 if only a single instanc… |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.2.1.43.33.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Defines the integer value of the attribute. The value of
the attribute is represented as an integer if the finAttributeTypeTC description for the attribute has the tag 'INTEGER:'. Depending upon the attr… |
Integer32r/w Constraints: range: -2-2147483647 |
.1.3.6.1.2.1.43.33.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Contains the octet string value of the attribute. The
value of the attribute is represented as a string if the finAttributeTypeTC description for the attribute has the tag 'OCTETS:'. Depending upon the a… |
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.2.1.43.33.1.1.4 |