ENERGY-OBJECT-CONTEXT-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
19
eoTable
table.1.3.6.1.2.1.231.1.1
·
1 row entry
·
14 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk eoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-CONTEXT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-CONTEXT-MIB::eoTable'
This table lists Energy Objects.
An entry describes the attributes of an Energy Object.
Whenever a new Energy Object is added or an existing
Energy Object is deleted, a row in the eoTable is added
or deleted.
Whenever a new Energy Object is added or an existing
Energy Object is deleted, a row in the eoTable is added
or deleted.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This variable uniquely identifies the power Ethernet
port to which a Power over Ethernet device is connected. If the Power over Ethernet MIB in RFC 3621 is supported by the SNMP agent managing the Energy Object, then th… |
PethPsePortIndexOrZero Type Constraints: range: 0..2147483647 |
.1.3.6.1.2.1.231.1.1.1.1 |
||||||||||||||
|
This variable uniquely identifies the group containing
the port to which a power over Ethernet device PSE is connected (RFC 3621). If the Power over Ethernet MIB (RFC 3621) is supported by the SNMP agent managing the E… |
PethPsePortGroupIndexOrZero Type Constraints: range: 0..2147483647 |
.1.3.6.1.2.1.231.1.1.1.2 |
||||||||||||||
|
This variable uniquely identifies the port component
(contained in the local chassis with the LLDP agent) as defined by the lldpLocPortNum in the LLDP-MIB and LLDP-MED-MIB. If the LLDP-MIB is supported by the SNMP agen… |
LldpPortNumberOrZero Type Constraints: range: 0..4096 |
.1.3.6.1.2.1.231.1.1.1.3 |
||||||||||||||
|
This object specifies a Media Access Control (MAC) address
of the Energy Object. |
SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.2.1.231.1.1.1.4 |
||||||||||||||
|
This object specifies the eoMgmtAddress type, i.e., an
IPv4 or IPv6 address. This object MUST be populated when eoMgmtAddress is populated. |
INET-ADDRESS-MIBInetAddressType Type Values:
|
.1.3.6.1.2.1.231.1.1.1.5 |
||||||||||||||
|
This object specifies the management address as an IPv4
address or IPv6 address of Energy Object. The IP address type, i.e. IPv4 or IPv6, is determined by the eoMgmtAddressType value. This object can be used as an alt… |
INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 |
.1.3.6.1.2.1.231.1.1.1.6 |
||||||||||||||
|
This object specifies a DNS name of the eoMgmtAddress.
This object can be used as an alternate key to help link the Energy Object with other keyed information that may be stored within the EnMS(s). A DNS Name must alwa… |
OctetString | .1.3.6.1.2.1.231.1.1.1.7 |
||||||||||||||
|
This object specifies the name of an Energy Management
Domain for the Energy Object. By default, this object should be an empty string. The value of eoDomainName must remain constant at least from one re-initializatio… |
SNMP-FRAMEWORK-MIBSnmpAdminStringr/w Type Constraints: range: 0..255 |
.1.3.6.1.2.1.231.1.1.1.8 |
||||||||||||||
|
This object specifies an administratively assigned name
to indicate the purpose an Energy Object serves in the network. For example, we can have a phone deployed to a lobby with eoRoleDescription as 'Lobb… |
SNMP-FRAMEWORK-MIBSnmpAdminStringr/w Type Constraints: range: 0..255 |
.1.3.6.1.2.1.231.1.1.1.9 |
||||||||||||||
|
This object specifies a list of keywords that can be
used to group Energy Objects for reporting or searching. The value is the zero-length string if no keywords have been configured. If multiple keywords are present, t… |
EnergyObjectKeywordListr/w Type Constraints: range: 0..2048 |
.1.3.6.1.2.1.231.1.1.1.10 |
||||||||||||||
|
This object specifies a ranking of how important the
Energy Object is (on a scale of 1 to 100) compared with other Energy Objects in the same Energy Management Domain. The ranking should provide a business or operation… |
Integer32r/w Constraints: range: 1-100 |
.1.3.6.1.2.1.231.1.1.1.11 |
||||||||||||||
|
This object describes the Energy Object category, which
indicates the expected behavior or physical property of the Energy Object, based on its design. An Energy Object can be a consumer(0), producer(1), meter(2), dist… |
Enumeration Enumerated Values:
|
.1.3.6.1.2.1.231.1.1.1.12 |
||||||||||||||
|
The eoAlternateKey object specifies an alternate key
string that can be used to identify the Energy Object. Since Energy Management Systems (EnMS) and Network Management Systems (NMSs) may need to correlate objects acro… |
SNMP-FRAMEWORK-MIBSnmpAdminStringr/w Type Constraints: range: 0..255 |
.1.3.6.1.2.1.231.1.1.1.13 |
||||||||||||||
|
This object describes the Power Interface for an Energy
Object. A Power Interface is an interface at which an Energy Object is connected to a power transmission medium, at which it can in turn receive power, provide po… |
Enumeration Enumerated Values:
|
.1.3.6.1.2.1.231.1.1.1.14 |
eoRelationTable
table.1.3.6.1.2.1.231.1.2
·
1 row entry
·
5 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk eoRelationTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-CONTEXT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-CONTEXT-MIB::eoRelationTable'
This table describes the relationships between Energy Objects.
An entry in this table specifies the Energy relationship
between Energy objects. Energy relations between two
Energy objects are defined in RFC 7326.
between Energy objects. Energy relations between two
Energy objects are defined in RFC 7326.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object is an arbitrary index to identify the Energy
Object related to another Energy Object. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.2.1.231.1.2.1.1 |
||||||||||||
|
This object specifies the Universally Unique Identifier
(UUID) of the peer (other) Energy Object. The UUID must comply with the specifications of UUID in UUID-TC-MIB. If the UUID of the Energy Object is … |
UUID-TC-MIBUUIDorZeror/w Type Constraints: range: 0range: 16 |
.1.3.6.1.2.1.231.1.2.1.2 |
||||||||||||
|
This object describes the relations between Energy
Objects. For each Energy Object, the relations between the other Energy Objects are specified using the bitmap. |
IANA-ENERGY-RELATION-MIBIANAEnergyRelationshipr/w Type Values:
|
.1.3.6.1.2.1.231.1.2.1.3 |
||||||||||||
|
The status controls and reflects the creation and
activation status of a row in this table to specify energy relationship between Energy Objects. An entry status may not be active(1) unless all objects in… |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.6.1.2.1.231.1.2.1.4 |
||||||||||||
|
This variable indicates the storage type for this row.
|
SNMPv2-TCStorageTyper/w Type Values:
Description: Describes the memory realization of a conceptual row. A row which is volatile(2) is lost upon reboot. A row which is either nonVolatile(3), permanent(4) or readOnly(5), is backed up by stable storage. A row which is … |
.1.3.6.1.2.1.231.1.2.1.5 |