ENERGY-OBJECT-CONTEXT-MIB

        Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code.  All rights reserved.
        
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).
        
This MIB is used for describing the identity and the
context information of Energy Objects.
    
Source file
ENERGY-OBJECT-CONTEXT-MIB
Last revised
Identity
energyObjectContextMIB
Base OID
1.3.6.1.2.1.231
Imported Objects
ENTITY-MIB entPhysicalIndex
IANA-ENERGY-RELATION-MIB IANAEnergyRelationship
INET-ADDRESS-MIB InetAddress InetAddressType
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-CONF MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Integer32 mib-2 MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC MacAddress RowStatus StorageType TEXTUAL-CONVENTION (no object page) TruthValue
UUID-TC-MIB UUIDorZero
Net-SNMP examples using the rfc MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ENERGY-OBJECT-CONTEXT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ENERGY-OBJECT-CONTEXT-MIB::energyObjectContextMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-CONTEXT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-CONTEXT-MIB::energyObjectContextMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (29)
.1.3.6.1.2.1.231
.1.3.6.1.2.1.231.0
.1.3.6.1.2.1.231.1
.1.3.6.1.2.1.231.1.1
.1.3.6.1.2.1.231.1.1.1
.1.3.6.1.2.1.231.1.1.1.1
.1.3.6.1.2.1.231.1.1.1.10
Integer32
.1.3.6.1.2.1.231.1.1.1.11
Enumeration
.1.3.6.1.2.1.231.1.1.1.12
.1.3.6.1.2.1.231.1.1.1.13
Enumeration
.1.3.6.1.2.1.231.1.1.1.14
.1.3.6.1.2.1.231.1.1.1.2
.1.3.6.1.2.1.231.1.1.1.3
.1.3.6.1.2.1.231.1.1.1.4
.1.3.6.1.2.1.231.1.1.1.5
.1.3.6.1.2.1.231.1.1.1.6
OctetString
.1.3.6.1.2.1.231.1.1.1.7
.1.3.6.1.2.1.231.1.1.1.8
.1.3.6.1.2.1.231.1.1.1.9
.1.3.6.1.2.1.231.1.2
.1.3.6.1.2.1.231.1.2.1
Integer32
.1.3.6.1.2.1.231.1.2.1.1
.1.3.6.1.2.1.231.1.2.1.2
.1.3.6.1.2.1.231.1.2.1.3
.1.3.6.1.2.1.231.1.2.1.4
.1.3.6.1.2.1.231.1.2.1.5
.1.3.6.1.2.1.231.2
.1.3.6.1.2.1.231.2.1
.1.3.6.1.2.1.231.2.2
Dependencies (9) 8 direct · 1 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Type Definitions (4)
OctetString range: 0..2048
Integer32 range: 0..4096
Integer32 range: 0..2147483647
Integer32 range: 0..2147483647
Conformance Groups (3)
This group contains the collection of all the objects
related to the EnergyObject.
.1.3.6.1.2.1.231.2.2.1
This group contains the collection of all the objects
related to the Energy Object.
.1.3.6.1.2.1.231.2.2.2
This group contains the collection of all objects
specifying the relationship between Energy Objects.
.1.3.6.1.2.1.231.2.2.3
Compliance Statements (2)

OID .1.3.6.1.2.1.231.2.1.1
When this MIB is implemented with support for
read-write, then such an implementation can
claim full compliance. Such devices can then
be both monitored and configured with this MIB.
Module Compliance of ENTITY-MIB with respect to
entity4CRCompliance MUST be supported.
Required groups
mandatory energyObjectContextMIBTableGroup
mandatory energyObjectRelationTableGroup
optional energyObjectOptionalMIBTableGroup A compliant implementation does not have to
implement.

OID .1.3.6.1.2.1.231.2.1.2
When this MIB is implemented without support for
read-write (i.e., in read-only mode), then such an
implementation can claim read-only compliance.
Such a device can then be monitored but cannot be
configured with this MIB.
Module Compliance of ENTITY-MIB with respect to
entity4CRCompliance MUST be supported.
Required groups
mandatory energyObjectContextMIBTableGroup
mandatory energyObjectRelationTableGroup
optional energyObjectOptionalMIBTableGroup A compliant implementation does not have to implement
the managed objects in this GROUP.