Storage System fan status change.
The agent has detected a change in the Fan Status of a storage
system. The variable cpqSsBoxFanStatus indicates the current
fan status.
cpqSsTempFailed
.1.3.6.1.4.1.232.0.8002
Storage System temperature failure.
The agent has detected that a temperature status has been set
to failed. The storage system will be shutdown.
cpqSsTempDegraded
.1.3.6.1.4.1.232.0.8003
Storage System temperature degraded.
The agent has detected a temperature status that has been set to
degraded. The storage system`s temperature is outside of the
normal operating range.
cpqSsTempOk
.1.3.6.1.4.1.232.0.8004
Storage System temperature ok.
The temperature status has been set to OK. The storage
system`s temperature has returned to normal operating range.
It may be reactivated by the administrator.
cpqSsSidePanelInPlace
.1.3.6.1.4.1.232.0.8005
Storage System side panel is in place.
The side panel status has been set to in place. The storage
system`s side panel has returned to a properly installed state.
cpqSsSidePanelRemoved
.1.3.6.1.4.1.232.0.8006
Storage System side panel is removed.
The side panel status has been set to removed. The storage
system`s side panel is not in a properly installed state. This
situation may result in improper cooling of the drives in the
storage system due to air flow changes caused by the missing
side panel.
cpqSsPwrSupplyDegraded
.1.3.6.1.4.1.232.0.8007
A storage system power supply status has been set to degraded.
cpqSs3FanStatusChange
.1.3.6.1.4.1.232.0.8008
Storage System fan status change.
The agent has detected a change in the Fan Status of a storage
system. The variable cpqSsBoxFanStatus indicates the current
fan status.
User Action: If the fan status is degraded or failed, replace
any failed fans.
cpqSs3TempFailed
.1.3.6.1.4.1.232.0.8009
Storage System temperature failure.
The agent has detected that a temperature status has been set to
failed. The storage system will be shutdown.
User Action: Shutdown the storage system as soon as possible.
Insure that the storage system environment is being cooled
properly and that no components are overheated.
cpqSs3TempDegraded
.1.3.6.1.4.1.232.0.8010
Storage System temperature degraded.
The agent has detected a temperature status that has been set to
degraded. The storage system`s temperature is outside of the
normal operating range.
User Action: Shutdown the storage system as soon as possible.
Insure that the storage system environment is being cooled
properly and that no components are overheated.
cpqSs3TempOk
.1.3.6.1.4.1.232.0.8011
Storage System temperature ok.
The temperature status has been set to OK. The storage
system`s temperature has returned to normal operating range.
It may be reactivated by the administrator.
User Action: None.
cpqSs3SidePanelInPlace
.1.3.6.1.4.1.232.0.8012
Storage System side panel is in place.
The side panel status has been set to in place. The storage
system`s side panel has returned to a properly installed state.
User Action: None.
cpqSs3SidePanelRemoved
.1.3.6.1.4.1.232.0.8013
Storage System side panel is removed.
The side panel status has been set to removed. The storage
system`s side panel is not in a properly installed state. This
situation may result in improper cooling of the drives in the
storage system due to air flow changes caused by the missing
side panel.
User Action: Replace the storage system side panel.
cpqSs3PwrSupplyDegraded
.1.3.6.1.4.1.232.0.8014
A storage system power supply status has been set to degraded.
cpqSs4PwrSupplyDegraded
.1.3.6.1.4.1.232.0.8015
A storage system power supply status has been set to degraded.
User Action: Take action to restore power or replace any failed
storage system power supply.
cpqSsExFanStatusChange
.1.3.6.1.4.1.232.0.8016
Storage system fan status change.
The agent has detected a change in the Fan Module Status of a
storage system. The variable cpqSsFanModuleStatus indicates the
current fan status.
User Action: If the fan status is degraded or failed, replace
any failed fans.
cpqSsExPowerSupplyStatusChange
.1.3.6.1.4.1.232.0.8017
Storage system power supply status change.
The agent has detected a change in the power supply status of a
storage system. The variable cpqSsPowerSupplyStatus indicates
the current status.
User Action: If the power supply status is failed, take action to
restore power or replace the failed power supply.
cpqSsExPowerSupplyUpsStatusChange
.1.3.6.1.4.1.232.0.8018
Storage system power supply UPS status change.
The agent has detected a change status of a UPS attached to a
storage system power supply. The variable
cpqSsPowerSupplyUpsStatus indicates the current status.
User Action: If cpqSsPowerSupplyUpsStatus is `powerFailed(4)` or
`batteryLow(5)`, take action to restore power to the UPS.
cpqSsExTempSensorStatusChange
.1.3.6.1.4.1.232.0.8019
Storage system temperature sensor status change.
The agent has detected a change in the status of a storage
system temperature sensor. The variable cpqSsTempSensorStatus
indicates the current status.
User Action: If cpqSsTempSensorStatus is `degraded(3)` or
`failed(4)`, shutdown the storage system as soon as possible.
Ensure that the storage system environment is being cooled properly
and that no components are overheated.
cpqSsEx2FanStatusChange
.1.3.6.1.4.1.232.0.8020
Storage system fan status change.
The agent has detected a change in the fan module status of a
storage system. The variable cpqSsFanModuleStatus indicates the
current fan status.
User Action: If cpqSsFanModuleStatus is `degraded(4)` or
`failed(5)`, replace any failed fans or fan modules.
cpqSsEx2PowerSupplyStatusChange
.1.3.6.1.4.1.232.0.8021
Storage system power supply status change.
The agent has detected a change in the power supply status of a
storage system. The variable cpqSsPowerSupplyStatus indicates
the current status.
User Action: If cpqSsPowerSupplyStatus is `failed(4)`, restore
power or replace the failed power supply.
cpqSsExBackplaneFanStatusChange
.1.3.6.1.4.1.232.0.8022
Storage system fan status change.
The agent has detected a change in the fan status of a storage
system. The variable cpqSsBackplaneFanStatus indicates the
current fan status.
User Action: If cpqSsBackplaneFanStatus is `degraded(4)`,
`degraded-Fan1Failed(7)`, `degraded-Fan2Failed(8)` or `failed(5)`,
replace the fan or fan modules.
cpqSsExBackplaneTempStatusChange
.1.3.6.1.4.1.232.0.8023
Storage system temperature status change.
The agent has detected a change in the status of the temperature
in a storage system. The variable cpqSsBackplaneTempStatus
indicates the current status.
User Action: If cpqSsBackplaneTempStatus is `degraded(4)` or
`failed(5)`, shutdown the storage system as soon as possible.
Ensure that the storage system environment is being cooled properly
and that no components are overheated.
cpqSsExBackplanePowerSupplyStatusChange
.1.3.6.1.4.1.232.0.8024
Storage system power supply status change.
The agent has detected a change in the power supply status of a
storage system. The variable cpqSsBackplaneFtpsStatus indicates
the current status.
User Action: If cpqSsBackplaneFtpsStatus is `degraded(4)`, restore
power or replace the failed power supply.
cpqSsExRecoveryServerStatusChange
.1.3.6.1.4.1.232.0.8025
Storage system recovery server option status change.
The agent has detected a change in the recovery server option
status of a storage system. The variable cpqSsChassisRsoStatus
indicates the current status.
User Action: If cpqSsChassisRsoStatus is `noSecondary(8)` or
`linkDown(10)`, ensure the secondary server is operational and all
cables are connected properly. If the RSO status is
`secondaryRunningAuto(12)` or `secondaryRunningUser(13)`, examine
the primary server for failed components.
cpqSs5FanStatusChange
.1.3.6.1.4.1.232.0.8026
Storage System fan status change.
The agent has detected a change in the Fan Status of a storage
system. The variable cpqSsBoxFanStatus indicates the current
fan status.
User Action: If the fan status is degraded or failed, replace
any failed fans.
cpqSs5TempStatusChange
.1.3.6.1.4.1.232.0.8027
Storage System temperature status change.
The agent has detected a change in the temperature status of a
storage system. The variable cpqSsBoxTempStatus indicates the
current temperature status.
User Action: If the temperature status is degraded or failed,
shutdown the storage system as soon as possible. Insure that
the storage system environment is being cooled properly and that
no components are overheated.
cpqSs5PwrSupplyStatusChange
.1.3.6.1.4.1.232.0.8028
Storage system power supply status change.
The agent has detected a change in the power supply status of a
storage system. The variable cpqSsBoxFltTolPwrSupplyStatus
indicates the current power supply status.
User Action: If the power supply status is degraded, take action
to restore power or replace the failed power supply.
cpqSs6FanStatusChange
.1.3.6.1.4.1.232.0.8029
Storage System fan status change.
The agent has detected a change in the Fan Status of a storage
system. The variable cpqSsBoxFanStatus indicates the current
fan status.
User Action: If cpqSsBoxFanStatus is `degraded(5)` or `failed(3)`,
replace any failed fans or fan modules.
cpqSs6TempStatusChange
.1.3.6.1.4.1.232.0.8030
Storage System temperature status change.
The agent has detected a change in the temperature status of a
storage system. The variable cpqSsBoxTempStatus indicates the
current temperature status.
User Action: If cpqSsBoxTempStatus is `degraded(3)` or `failed(4)`,
shutdown the storage system as soon as possible. Ensure that
the storage system environment is being cooled properly and that
no components are overheated.
cpqSs6PwrSupplyStatusChange
.1.3.6.1.4.1.232.0.8031
Storage system power supply status change.
The agent has detected a change in the power supply status of a
storage system. The variable cpqSsBoxFltTolPwrSupplyStatus
indicates the current power supply status.
User Action: If cpqSsBoxFltTolPwrSupplyStatus is `degraded(3)`,
restore power or replace the failed power supply.
cpqSsConnectionStatusChange
.1.3.6.1.4.1.232.0.8032
Storage system connection status change.
The agent has detected a change in the connection status of a storage
system. The variable cpqSSboxConnectionStatus indicates the current
connection status.
User Action: If cpqSsBoxConnectionStatus is `notConnected(4)`,
restore the connection between the HBA and the storage system
cpqSsGSIStatusChange
.1.3.6.1.4.1.232.0.8033
Storage system Global Service Indicator Status Change.
The agent has detected a change in the Global Service Indicator
status of a storage system. The variable cpqSsBoxGSIStatus
indicates the current GSI supply status. The variable
cpqSsBoxGSIMessages contains the error messages sent from
the storage enclosure.
User Action: Refer to the User Documentation for the storage
enclosure to find recommended actions for specified messages.
cpqSsFanStatusChange
.1.3.6.1.4.1.232.8.0.1
Storage System fan status change.
The agent has detected a change in the Fan Status of a storage
system. The variable cpqSsBoxFanStatus indicates the current
fan status.