potsIfTable

table
.0.14.1.1 · 1 row entry · 13 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk potsIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfTable'
The potsIfTable contains configuration information
for the POTS outlets.
potsIfEntry row .0.14.1.1.1
Indexes
Column Syntax OID
Identification number of the used slot.
Integer32
Constraints:
range: 0-31
.0.14.1.1.1.1
Identification number of the used unit.
Integer32
Constraints:
range: 0-31
.0.14.1.1.1.2
The type of the connected device on socket a.

Possible values are:
- any(1), (multifunctional)
- fax(2),
- telephony(3),
- modem(4),
- disable(5),
Enumerationr/w
Enumerated Values:
1any
2fax
3telephony
4modem
5disable
6doorintercom
7answering
8emergency
9alarmInput
.0.14.1.1.1.3
Type of outlet.
Enumeration
Enumerated Values:
1fxo
2fxs
.0.14.1.1.1.4
This variable allows for taking an POTS interface out of/in
service w/o having to touch the configuration.

Besides, it is possible to initiate a reconfiguration for that
interface in case a mismatch in co…
Enumerationr/w
Enumerated Values:
1down
2up
3reconfig
.0.14.1.1.1.5
The operational state of an interface is indicated via this
variable.
Possible values are:
- down(1),
- running(2),
- fail(3),
- not-connected(4),
- stopped(5),
- stopping(6),
Enumeration
Enumerated Values:
1down
2running
3fail
4not-connected
5stopped
6stopping
7starting
.0.14.1.1.1.6
Reference to the FXS or FXO table.
PotsIfIndex .0.14.1.1.1.7
Teletax (metering pulse) level:
for FXS lines: output level
for FXO lines: minimum level
Integer32r/w
Constraints:
range: -50-0
.0.14.1.1.1.8
Teletax (metering pulse) frequency:
1: no teletax output/reception
3: 12 kHz
4: 16 kHz
Enumerationr/w
Enumerated Values:
1off
3freq12khz
4freq16khz
.0.14.1.1.1.9
Selection of the coefficient set provided
by the FXS or FXO line driver. This allows
to use specific settings with e.g. resistive or
complex line impedances. Supported values are:
600: 600 ohms (resistive)
11…
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.1.1.10
Amplification or attenuation (negative gain)
of outgoing audio in dB.
dBInteger32r/w
Constraints:
range: -30-10
.0.14.1.1.1.11
Amplification or attenuation (negative gain)
of incoming audio in dB.
dBInteger32r/w
Constraints:
range: -30-10
.0.14.1.1.1.12
Limit for time interval between two consecutive
dialling digits.
sInteger32r/w
Constraints:
range: 1-99
.0.14.1.1.1.13
.0.14.1.2 · 1 row entry · 42 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk potsIfFxoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfFxoTable'
The potsIfFxoTable contains configuration information
for the FXO outlets.
potsIfFxoEntry row .0.14.1.2.1
Column Syntax OID
Index of the FXO interface.
PotsIfIndexr/w .0.14.1.2.1.1
Dial out flash time (ms).
msSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.2.1.2
Type of tone:
off(1) no dial tone detection
single(2) detect just one tone rhythm
dual(3) detect also an alternative tone rhythm

Enable dial tone detection. The following entries describes the
Enumerationr/w
Enumerated Values:
1off
2single
3dual
.0.14.1.2.1.3
Activation time for dial tone detection in seconds. When this
time is reached dial tone detection will be switched off.
A zero value keeps dial tone detection endlessly active.
sSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.2.1.4
minimum dial tone level.
dBReceiveLevelr/w
Type Constraints:
range: -50..0
.0.14.1.2.1.5
Frequency of the expected dial tone (Hz).
HzToneFrequencyr/w
Type Constraints:
range: 300..3400
.0.14.1.2.1.6
Cadence of the expected dial tone.

The cadence definition consists of times of activity, times
of no activity and some control information. All information
is concatenated to one string and all times are…
CadenceStringr/w
Type Constraints:
range: 0..127
.0.14.1.2.1.7
Dial tone timing tolerance (%).
%CadenceTimingTolerancer/w
Type Constraints:
range: 0..100
.0.14.1.2.1.8
Alternative dial tone frequncy (Hz).
HzToneFrequencyr/w
Type Constraints:
range: 300..3400
.0.14.1.2.1.9
Alternative dial tone cadence. For a description of
allowed format refer to potsIfFxoDialToneOrgCadence.
CadenceStringr/w
Type Constraints:
range: 0..127
.0.14.1.2.1.10
Alternative dial tone timing tolerance (%).
%CadenceTimingTolerancer/w
Type Constraints:
range: 0..100
.0.14.1.2.1.11
Type of tone:
off(1) no busy tone detection
single(2) detect just one tone rhythm
dual(3) detect also an alternative tone rhythm

Enable busy tone detection.
Enumerationr/w
Enumerated Values:
1off
2single
3dual
.0.14.1.2.1.12
Activation time for busy tone detection in seconds. When this
time is reached busy tone detection will be switched off.
A zero value keeps busy tone detection endlessly active.
sSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.2.1.13
Minimum busy tone level (dB).
dBReceiveLevelr/w
Type Constraints:
range: -50..0
.0.14.1.2.1.14
Busy tone frequncy (Hz).
HzToneFrequencyr/w
Type Constraints:
range: 300..3400
.0.14.1.2.1.15
Busy tone cadence. For a description of allowed
format refer to potsIfFxoDialToneOrgCadence.
CadenceStringr/w
Type Constraints:
range: 0..127
.0.14.1.2.1.16
Busy tone timing tolerance (%).
%CadenceTimingTolerancer/w
Type Constraints:
range: 0..100
.0.14.1.2.1.17
Alternative busy tone frequncy.
ToneFrequencyr/w
Type Constraints:
range: 300..3400
.0.14.1.2.1.18
Alternative busy tone cadence. For a description of
allowed format refer to potsIfFxoDialToneOrgCadence.
CadenceStringr/w
Type Constraints:
range: 0..127
.0.14.1.2.1.19
Alternative busy tone timing tolerance (%).
%CadenceTimingTolerancer/w
Type Constraints:
range: 0..100
.0.14.1.2.1.20
Dial-out mode (1: pulse, 2: DTMF).
Enumerationr/w
Enumerated Values:
1pulse
2dtmf
.0.14.1.2.1.21
Waiting time before dialout starts (ms).
msSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.2.1.22
Dial-in mode (1: off, 2: DTMF, 3: UEFS).
Enumerationr/w
Enumerated Values:
1off
2dtmf
3uefs
.0.14.1.2.1.23
The progress tone is used for dial in mode 'DTMF' only.
Other dial in modes will ignore this entry. The progress tone
will signal the caller when to start to dial the subscriber
number. After reception of the first di…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.0.14.1.2.1.24
Index of the progress tone definition in phoneIfToneTable.
ToneTabIndexr/w .0.14.1.2.1.25
Pulse dialling break time (ms).
msInteger32r/w
Constraints:
range: 30-200
.0.14.1.2.1.26
Pulse dialling make time (ms).
msInteger32r/w
Constraints:
range: 30-200
.0.14.1.2.1.27
DTMF dialling interdigit time (ms).
msInteger32r/w
Constraints:
range: 100-500
.0.14.1.2.1.28
DTMF tone level (dB).
dBTransmitLevelr/w
Type Constraints:
range: -30..0
.0.14.1.2.1.29
DTMF tone duration (ms).
msInteger32r/w
Constraints:
range: 50-250
.0.14.1.2.1.30
DTMF dialling interdigit time (ms).
msInteger32r/w
Constraints:
range: 50-250
.0.14.1.2.1.31
Minimum data transmission level (dB).
dBTransmitLevelr/w
Type Constraints:
range: -30..0
.0.14.1.2.1.32
Allowed on-hook data transmission modes:
dt-as: data transmission prior to ringing with DT-AS
dt-as-pol-rev: data transmission prior to ringing with DT-AS
and polarity reversal
rp-as: …
Bitsr/w
Enumerated Values:
0dt-as
1dt-as-pol-rev
2rp-as
3during-ringing
4dtmf
.0.14.1.2.1.33
Selection of off-hook data transmission mode:
1: no off-hook data transmission
2: data transmission prior using DT-AS
Enumerationr/w
Enumerated Values:
1off
2dt-as
.0.14.1.2.1.34
Fax tone detection. Tones to detect according to ITU T.30:
cng: fax announce tone 1100 Hz
ced: fax answer tone 2100 Hz
dis: digital identification signal V.21
Bitsr/w
Enumerated Values:
0cng
1ced
2dis
.0.14.1.2.1.35
Detection of key break as a release condition.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.0.14.1.2.1.36
Detection of dial tones as a trigger for outgoing dial.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.0.14.1.2.1.37
Index of the normal dial tone definition in
phoneIfToneTable used by dial out tone detection.
ToneDefTabIndexr/w .0.14.1.2.1.38
Index of the special dial tone definition in
phoneIfToneTable used by dial out tone detection.
ToneDefTabIndexr/w .0.14.1.2.1.39
Detection of tones after dialling and during a connection
to catch a release condition.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.0.14.1.2.1.40
Index of the busy tone definition in phoneIfToneTable
used by concurrent tone detection.
ToneDefTabIndexr/w .0.14.1.2.1.41
Index of the congestion tone definition in phoneIfToneTable
used by concurrent tone detection.
ToneDefTabIndexr/w .0.14.1.2.1.42
.0.14.1.3 · 1 row entry · 17 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk potsIfFxsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfFxsTable'
The potsIfFxsTable contains configuration information
for the FXS outlets.
potsIfFxsEntry row .0.14.1.3.1
Column Syntax OID
Index of the FXS interface.
PotsIfIndexr/w .0.14.1.3.1.1
Minimum flash duration (ms). Flash pulses below this
value will be ignored.
msSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.3.1.2
Maximum flash duration (ms). Flash pulses above this
value will be interpreted as hook-on.
msSNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.0.14.1.3.1.3
Peak value of sinusoidal ringing voltage.
VpeakInteger32r/w
Constraints:
range: 0-150
.0.14.1.3.1.4
Frequency of sinusoidal ringing voltage.
Enumerationr/w
Enumerated Values:
1freq25hz
2freq50hz
.0.14.1.3.1.5
The ringing table index is the reference to
all ringing cadences used for this extension.
Definitions are in phoneIfRingTable.
RingTabIndexr/w .0.14.1.3.1.6
The tone table index refers to the tones
used for this extension. Definitions are
in phoneIfToneTable
ToneTabIndexr/w .0.14.1.3.1.7
Allowed data transmission message types:
setup - call setup message
mwi - message waiting indicator message
aoc - advice of charge message
sms - short message service message
Bitsr/w
Enumerated Values:
0setup
1mwi
2aoc
3sms
.0.14.1.3.1.8
Allowed data transmission parameters (see ETSI EN 300 659-3).
Not selected elements will be filtered out and not sent to
the subscriber.
Bitsr/w
Enumerated Values:
0date-time
1calling-line-id
2called-line-id
3reason-for-absence-of-cli
4calling-party-name
5reason-for-absence-of-cpn
6visual-indicator
7message-identification
8last-message-cli
9complementary-date-time
10complementary-cli
11call-type
12first-cli
13no-of-messages
14charge
15additional-charge
16duration-of-call
17network-provider-id
18carrier-id
19select-terminal-function
20display-information
21service-information
.0.14.1.3.1.9
Level of the data transmission signal (dB).
dBTransmitLevelr/w
Type Constraints:
range: -30..0
.0.14.1.3.1.10
Index of the timer set to be used for on-hook and off-hook
data transmission.
DataLinkTimerTabIndexr/w .0.14.1.3.1.11
Selection of on-hook data transmission mode:
1: no on-hook data transmission
2: data transmission prior to ringing with DT-AS
3: data transmission prior to ringing with DT-AS
and polarity reversal
4: data trans…
Enumerationr/w
Enumerated Values:
1off
2dt-as
3dt-as-pol-rev
4rp-as
5during-ringing
6dtmf
.0.14.1.3.1.12
Selection of off-hook data transmission mode:
1: no off-hook data transmission
2: data transmission prior using DT-AS
Enumerationr/w
Enumerated Values:
1off
2dt-as
.0.14.1.3.1.13
Pulse dialling break time minimum (ms). Break pulses below
this limit will be ignored.
msInteger32r/w
Constraints:
range: 10-100
.0.14.1.3.1.14
Pulse dialling break time maximum (ms). A pause time above
this limit is regarded as on-hook signal.
msInteger32r/w
Constraints:
range: 50-200
.0.14.1.3.1.15
Pulse dialling make time minimum (ms). Make pulses below
this limit will be ignored.
msInteger32r/w
Constraints:
range: 10-100
.0.14.1.3.1.16
Pulse dialling make time maximum (ms). A pause time above
this limit finishes the pulse counting and this digit is
regarded as complete.
msInteger32r/w
Constraints:
range: 10-300
.0.14.1.3.1.17
.0.14.1.4 · 1 row entry · 19 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk potsIfDataLinkTimerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfDataLinkTimerTable'
The potsIfDataLinkTimerTable the contains timer values (in ms)
controlling on-hook and off-hook data transmission service 
according to ETSI EN 300 659. The reception of data is 
controlled with timers according to the minimum and maximum
values given in the ETSI standard.
potsIfDataLinkTimerEntry row .0.14.1.4.1
Column Syntax OID
Index of the set of timers which is following up.
DataLinkTimerTabIndexr/w .0.14.1.4.1.1
Timer T0 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 100-550
.0.14.1.4.1.2
Timer T1 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 45-500
.0.14.1.4.1.3
Timer T2 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 200-500
.0.14.1.4.1.4
Timer T3 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 500-800
.0.14.1.4.1.5
Timer T4 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 45-500
.0.14.1.4.1.6
Timer T5 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 500-2000
.0.14.1.4.1.7
Timer T6 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 200-3000
.0.14.1.4.1.8
Timer T7 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 250-700
.0.14.1.4.1.9
Timer T8 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 200-500
.0.14.1.4.1.10
Timer T9 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 0-150
.0.14.1.4.1.11
Timer T10 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 0-150
.0.14.1.4.1.12
Timer T11 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 40-55
.0.14.1.4.1.13
Timer T12 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 55-200
.0.14.1.4.1.14
Timer T13 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 40-120
.0.14.1.4.1.15
Timer T14 according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 155-165
.0.14.1.4.1.16
Timer RP-AS according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 200-300
.0.14.1.4.1.17
Timer DT-AS on-hook according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 90-110
.0.14.1.4.1.18
Timer DT-AS off-hook according to ETSI EN 300 659.
Integer32r/w
Constraints:
range: 75-85
.0.14.1.4.1.19