potsIfFxsDialPulseMaxTimePause

BINTEC-POTS-MIB · .0.14.1.3.1.17

Object

column r/w msInteger32
Pulse dialling make time maximum (ms). A pause time above
this limit finishes the pulse counting and this digit is
regarded as complete.

Context

MIB
BINTEC-POTS-MIB
OID
.0.14.1.3.1.17
Type
column
Access
readwrite
Status
current
Units
ms
Parent
potsIfFxsEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfFxsDialPulseMaxTimePause'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BINTEC-POTS-MIB::potsIfFxsDialPulseMaxTimePause.<potsIfFxsIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BINTEC-POTS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BINTEC-POTS-MIB::potsIfFxsDialPulseMaxTimePause'

Syntax

msInteger32

Values & Constraints

Object Constraints
range: 10-300