Enumeration
Type of tone:
off(1) no dial tone detection
single(2) detect just one tone rhythm
dual(3) detect also an alternative tone rhythm
Enable dial tone detection. The following entries describes the
parameters of the expected tone. It consists of time, level,
frequency, rhythm and tolerance values.
There are legacy central offices in some countries which
uses differently sequenced tones. So beside the original
tone description an alternative description can be used to
detect those tones also.
Another aspect is the allowed deviation from the expected
tone rhythm which is quite different in the national telephone
networks. To take this fact into account the tolerance entries
determines how precise the given rhythms should be proven.