zxAnCfmMepTestInterval

ZTE-AN-CFM-MIB · .1.3.6.1.4.1.3902.1015.62.1.3.1.1.60

Object

column r/w milliseconds Integer32
The interval value for ETH-Test messages transmitted by the MEP.
the default value is 1000 milliseconds.

Context

MIB
ZTE-AN-CFM-MIB
OID
.1.3.6.1.4.1.3902.1015.62.1.3.1.1.60
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
zxAnCfmMepEntry
Table
zxAnCfmMepTable
Siblings
65

Syntax

milliseconds Integer32

Values & Constraints

Object Constraints
range: 100-10000