xupsRecepCumulativePowerUsage
XUPS-MIB ·
.1.3.6.1.4.1.534.1.12.2.1.9
Object
column
r/w
Wh Integer32
Units are Watt-hours.This is the energy consumed since the last reset. This object is writable so that it can be reset to 0. When it is written to 0, the xupsRecepCumulativePowerUsageTimer will be reset to 0 as well.
Context
- MIB
- XUPS-MIB
- OID
.1.3.6.1.4.1.534.1.12.2.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Wh
- Parent
- xupsRecepEntry
- Table
- xupsRecepTable
- Siblings
- 9
Syntax
Wh Integer32
Values & Constraints
Object Constraints
range: 0-2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsRecepIndex The number of the Receptacle. Serves as index for Receptacle table. | column | Integer32 | .1.3.6.1.4.1.534.1.12.2.1.1 |
| xupsRecepCumulativePowerUsageTimer Time in seconds since the cumulative power usage was last reset. | column | Seconds SNMPv2-SMICounter32 | .1.3.6.1.4.1.534.1.12.2.1.10 |
| xupsRecepStatus The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off,
4=Off w/Pending ON, 5=Unknown, 6=Reserved for future,
7=Failed in Closed position, 8=Failed in Open position. | column | Enumeration | .1.3.6.1.4.1.534.1.12.2.1.2 |
| xupsRecepOffDelaySecs The Delay until the Receptacle is turned Off. Setting
this value to other than -1 will cause the UPS output to
turn off after the number of seconds (0 is immediately).
Settin… | column | seconds Integer32 | .1.3.6.1.4.1.534.1.12.2.1.3 |
| xupsRecepOnDelaySecs The Delay until the Receptacle is turned On. Setting
this value to other than -1 will cause the UPS output to
turn on after the number of seconds (0 is immediately).
Setting … | column | seconds Integer32 | .1.3.6.1.4.1.534.1.12.2.1.4 |
| xupsRecepAutoOffDelay The delay after going On Battery until the Receptacle is
automatically turned Off. A value of -1 means that this Output should
never be turned Off automatically, but must be tu… | column | seconds Integer32 | .1.3.6.1.4.1.534.1.12.2.1.5 |
| xupsRecepAutoOnDelay Seconds delay after the Outlet is signaled to turn On before the Output is
Automatically turned ON. A value of -1 means that this Output should never
be turned On automatically, b… | column | seconds Integer32 | .1.3.6.1.4.1.534.1.12.2.1.6 |
| xupsRecepShedSecsWithRestart Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Un… | column | seconds Integer32 | .1.3.6.1.4.1.534.1.12.2.1.7 |
| xupsRecepHourlyPowerUsage Units are Watt-hours.This is the energy consumed during the last hour. | column | Wh Integer32 | .1.3.6.1.4.1.534.1.12.2.1.8 |