xupsOutputTotal
XUPS-MIB ·
.1.3.6.1.4.1.534.1.4.9
Object
node
No description available.
Context
- MIB
- XUPS-MIB
- OID
.1.3.6.1.4.1.534.1.4.9- Type
- node
- Parent
- xupsOutput
- Siblings
- 9
- Children
- 5
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsOutputLoad The UPS output load in percent of rated capacity. | scalar | percent Integer32 | .1.3.6.1.4.1.534.1.4.1 |
| xupsOutputStatus The present status of the AC output of the UPS.
The enumeration outputNotPowered(1) indicates that the output is not powered.
outputNotProtected(2) indicates that the output is … | scalar | Enumeration | .1.3.6.1.4.1.534.1.4.10 |
| xupsOutputFrequency The measured UPS output frequency in tenths of Hz. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.534.1.4.2 |
| xupsOutputNumPhases The number of metered output phases. | scalar | Integer32 | .1.3.6.1.4.1.534.1.4.3 |
| xupsOutputTable A list of output table entries. The number of entries
is given by the value of xupsOutputNumPhases. | table | - | .1.3.6.1.4.1.534.1.4.4 |
| xupsOutputSource The present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened … | scalar | Enumeration | .1.3.6.1.4.1.534.1.4.5 |
| xupsOutputHourlyPowerUsage Units are Watt-hours.This is the energy consumed during the last hour. | scalar | Wh Integer32 | .1.3.6.1.4.1.534.1.4.6 |
| xupsOutputCumulativePowerUsage Units are Watt-hours.This is the energy consumed since the last reset.
This object is writable so that it can be reset to 0.
When it is written to 0, the xupsOutputCumulativeWhTim… | scalar | Wh Integer32 | .1.3.6.1.4.1.534.1.4.7 |
| xupsOutputCumulativePowerUsageTimer Time in seconds since the cumulative power usage was last reset. | scalar | Seconds SNMPv2-SMICounter32 | .1.3.6.1.4.1.534.1.4.8 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsOutputAverageVoltage The measured output voltage from the UPS meters in volts.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase voltage. | scalar | RMS Volts Integer32 | .1.3.6.1.4.1.534.1.4.9.1 |
| xupsOutputTotalCurrent The measured output current from the UPS meters in tenth of amps.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase current. | scalar | RMS tenth of Amps Integer32 | .1.3.6.1.4.1.534.1.4.9.2 |
| xupsOutputTotalWatts The measured output active power in watts.
Sum of all the simple phase watts. | scalar | Watts Integer32 | .1.3.6.1.4.1.534.1.4.9.3 |
| xupsOutputTotalVA The measured output apparent power in VA.
Sum of all the simple phase VA. | scalar | VA Integer32 | .1.3.6.1.4.1.534.1.4.9.4 |
| xupsOutputAveragePowerFactor Indicates the total power factor of the output in hundredths.
0.92 would be returned as 92. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.534.1.4.9.5 |