xupsOutput
XUPS-MIB ·
.1.3.6.1.4.1.534.1.4
Object
node
No description available.
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsIdent | node | - | .1.3.6.1.4.1.534.1.1 |
| xupsConfig | node | - | .1.3.6.1.4.1.534.1.10 |
| xupsConformance | node | - | .1.3.6.1.4.1.534.1.100 |
| xupsTrapControl | node | - | .1.3.6.1.4.1.534.1.11 |
| xupsRecep | node | - | .1.3.6.1.4.1.534.1.12 |
| xupsTopology | node | - | .1.3.6.1.4.1.534.1.13 |
| xupsAgent | node | - | .1.3.6.1.4.1.534.1.14 |
| xupsBattery | node | - | .1.3.6.1.4.1.534.1.2 |
| xupsInput | node | - | .1.3.6.1.4.1.534.1.3 |
| xupsBypass | node | - | .1.3.6.1.4.1.534.1.5 |
| xupsAlarm | node | - | .1.3.6.1.4.1.534.1.7 |
| xupsTest | node | - | .1.3.6.1.4.1.534.1.8 |
| xupsControl | node | - | .1.3.6.1.4.1.534.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsOutputLoad The UPS output load in percent of rated capacity. | scalar | percent Integer32 | .1.3.6.1.4.1.534.1.4.1 |
| xupsOutputStatus The present status of the AC output of the UPS.
The enumeration outputNotPowered(1) indicates that the output is not powered.
outputNotProtected(2) indicates that the output is … | scalar | Enumeration | .1.3.6.1.4.1.534.1.4.10 |
| xupsOutputFrequency The measured UPS output frequency in tenths of Hz. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.534.1.4.2 |
| xupsOutputNumPhases The number of metered output phases. | scalar | Integer32 | .1.3.6.1.4.1.534.1.4.3 |
| xupsOutputTable A list of output table entries. The number of entries
is given by the value of xupsOutputNumPhases. | table | - | .1.3.6.1.4.1.534.1.4.4 |
| xupsOutputSource The present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened … | scalar | Enumeration | .1.3.6.1.4.1.534.1.4.5 |
| xupsOutputHourlyPowerUsage Units are Watt-hours.This is the energy consumed during the last hour. | scalar | Wh Integer32 | .1.3.6.1.4.1.534.1.4.6 |
| xupsOutputCumulativePowerUsage Units are Watt-hours.This is the energy consumed since the last reset.
This object is writable so that it can be reset to 0.
When it is written to 0, the xupsOutputCumulativeWhTim… | scalar | Wh Integer32 | .1.3.6.1.4.1.534.1.4.7 |
| xupsOutputCumulativePowerUsageTimer Time in seconds since the cumulative power usage was last reset. | scalar | Seconds SNMPv2-SMICounter32 | .1.3.6.1.4.1.534.1.4.8 |
| xupsOutputTotal | node | - | .1.3.6.1.4.1.534.1.4.9 |