wtWebio577xxEA12x6RelHttpPort
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.51.3.1.3.2.4
Object
scalar
mandatory
r/w
Integer32
Definition of the standard HTML port (Default: 80).
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.51.3.1.3.2.4- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebio577xxEA12x6RelHTTP
- Siblings
- 3
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebio577xxEA12x6RelStartup mandatory Binary coded start page, more than one page must not be selected:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2: user.htm
Bit 1: home.htm
Bit 0: index.… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.1 |
| wtWebio577xxEA12x6RelGetHeaderEnable mandatory If bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
Octet 1: unused
Octet 2: unused
… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.2 |
| wtWebio577xxEA12x6RelHttpInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.3 |