wtWebio577xxEA12x6RelHttpInputTrigger
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.51.3.1.3.2.3
Object
scalar
mandatory
r/w
OctetString
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.51.3.1.3.2.3- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebio577xxEA12x6RelHTTP
- Siblings
- 3
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebio577xxEA12x6RelStartup mandatory Binary coded start page, more than one page must not be selected:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2: user.htm
Bit 1: home.htm
Bit 0: index.… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.1 |
| wtWebio577xxEA12x6RelGetHeaderEnable mandatory If bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
Octet 1: unused
Octet 2: unused
… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.2 |
| wtWebio577xxEA12x6RelHttpPort mandatory Definition of the standard HTML port (Default: 80). | scalar | Integer32 | .1.3.6.1.4.1.5040.1.2.51.3.1.3.2.4 |