vmwNsxTFederationLmToLmSynchronizationError

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.32.0.3

Object

notification
The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
failed for more than 15 minutes.
          
Action required:
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
   state between the remote locations. If a remote location is connected but not synchronized,
   it is possible that the location is still in the process of master resolution. In
   this case, wait for around 10 seconds and try invoking the CLI again to
   check for the state of the remote location. If a location is disconnected, try the next
   step.
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
   in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
   check for flakiness in WAN connectivity. If there are no physical network
   connectivity issues, try the next step.
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
   location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
   communication errors. In addition, also look for errors being logged by the
   nsx-appl-proxy subcomponent within /var/log/syslog.

Context

MIB
VMWARE-NSX-MIB
OID
.1.3.6.1.4.1.6876.120.1.0.32.0.3
Type
notification
Status
current
Parent
vmwNsxTFederationFeature
Siblings
25

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects