vmwNsxTFederationGMToLMSynchronizationError

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.32.0.23

Object

notification
Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
failed for the vmwNsxTDataCenterFlowIdentifier for an extended period. Reason: vmwNsxTDataCenterSyncIssueReason.
          
Action required:
1. Check the network connectivity between remote site and local site via ping.
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
3. Ensure the async-replicator service is running on both local and remote sites.
Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the
`get service async_replicator` NSX CLI command to determine if the service is running.
If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or
the `restart service async_replicator` NSX CLI to restart the service.
4. Check /var/log/async-replicator/ar.log to see if there are errors reported.
5. Collect a support bundle and contact the NSX support team.

Context

MIB
VMWARE-NSX-MIB
OID
.1.3.6.1.4.1.6876.120.1.0.32.0.23
Type
notification
Status
current
Parent
vmwNsxTFederationFeature
Siblings
25

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects