vmwNsxTFederationGMToLMSynchronizationWarning

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.32.0.25

Object

notification
Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the
vmwNsxTDataCenterFlowIdentifier. Reason: vmwNsxTDataCenterSyncIssueReason
          
Action required:
1. Check the network connectivity between remote site and local site via ping.
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
3. Ensure the async-replicator service is running on both local and remote sites.
   Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the
   `get service async_replicator` NSX CLI command to determine if the service is running.
   If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or
   the `restart service async_replicator` NSX CLI to restart the service.
4. Check /var/log/async-replicator/ar.log to see if there are errors reported.