tlpUpsDevicePowerOnDelay
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.4
Object
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tlpUpsDeviceEntry
- Table
- tlpUpsDeviceTable
- Siblings
- 10
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpUpsDeviceMainLoadState The current state of the main output of the device. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.1 |
| tlpUpsDeviceLastShutdownReason The last unit shut down reason. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.10 |
| tlpUpsDeviceOutputCurrentPrecision Output current is reported by tlpUpsOutputLineCurrent, tlpUpsOutputLineCurrentMin and
tlpUpsOutputLineCurrentMax. These values are all reported in hundredths(0.01A),which
accomm… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.11 |
| tlpUpsDeviceMainLoadControllable Indicates whether or not the main output is controllable, and whether
the ups can be turned off and on. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.2 |
| tlpUpsDeviceMainLoadCommand Reading this value will always return 0. Setting this value to
turnOff(1) will turn off the main output of the ups. Setting this
value to turnOn(2) will turn on the main output of… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.3 |
| tlpUpsDeviceTestDate The date of the last self-test run on the ups, in the format YYYY-MM-DD. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.5 |
| tlpUpsDeviceTestResultsStatus The result of the last self-test run on the ups. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.6 |
| tlpUpsDeviceTemperatureC The ambient temperature at or near the ups casing. Temperature
measurements are not supported on all models. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.7 |
| tlpUpsDeviceTemperatureF The ambient temperature at or near the ups casing. Temperature
measurements are not supported on all models. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.8 |
| tlpUpsDeviceLastACFailureReason The last AC failure reason. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.9 |