tlpUpsDeviceOutputCurrentPrecision
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.11
Object
column
Enumeration
Output current is reported by tlpUpsOutputLineCurrent, tlpUpsOutputLineCurrentMin and tlpUpsOutputLineCurrentMax. These values are all reported in hundredths(0.01A),which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpUpsOutputLineCurrent reports 530 and tlpUpsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- tlpUpsDeviceEntry
- Table
- tlpUpsDeviceTable
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | wholeNumber |
1 | tenths |
2 | hundredths |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpUpsDeviceMainLoadState The current state of the main output of the device. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.1 |
| tlpUpsDeviceLastShutdownReason The last unit shut down reason. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.10 |
| tlpUpsDeviceMainLoadControllable Indicates whether or not the main output is controllable, and whether
the ups can be turned off and on. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.2 |
| tlpUpsDeviceMainLoadCommand Reading this value will always return 0. Setting this value to
turnOff(1) will turn off the main output of the ups. Setting this
value to turnOn(2) will turn on the main output of… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.3 |
| tlpUpsDevicePowerOnDelay The configurable delay value, which sets the amount of additional
time a given device will wait before it connects to a valid AC
source. By default the delay value is set to 0. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.4 |
| tlpUpsDeviceTestDate The date of the last self-test run on the ups, in the format YYYY-MM-DD. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.5 |
| tlpUpsDeviceTestResultsStatus The result of the last self-test run on the ups. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.6 |
| tlpUpsDeviceTemperatureC The ambient temperature at or near the ups casing. Temperature
measurements are not supported on all models. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.7 |
| tlpUpsDeviceTemperatureF The ambient temperature at or near the ups casing. Temperature
measurements are not supported on all models. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | 0.1 degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.8 |
| tlpUpsDeviceLastACFailureReason The last AC failure reason. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.2.1.1.9 |