tlpCoolingOffOnInputContact
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.5.5.1.1.10
Object
column
r/w
Enumeration
Indicates if the unit should stop cooling when input contact is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.5.5.1.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tlpCoolingConfigEntry
- Table
- tlpCoolingConfigTable
- Siblings
- 24
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | turnOff |
1 | alarmOnly |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpCoolingAutoStart Specifies if the unit should start automatically on power up.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.1 |
| tlpCoolingOffOnLeak Indicates if the unit should stop cooling when leak input is activated. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.11 |
| tlpCoolingWaterLeakContactType The water leak contact type. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.12 |
| tlpCoolingAirFilterInterval The number of weeks before the air filter needs to be changed.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | weeks SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.13 |
| tlpCoolingAirFilterAlarm When enabled, an alarm should occur when the maximum number of air filter run hours
has been exceeded. If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | hours Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.14 |
| tlpCoolingMaxAirFilterRunHours The maximum interval for air filter run hours before warning is annunciated.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.15 |
| tlpCoolingStartTimer The unit will start operate after the specified timer elapsed. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.16 |
| tlpCoolingStopTimer The unit will switch to standby mode after the specified timer elapsed. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.17 |
| tlpCoolingEnergyMode This option enables or disables the energy saving mode.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.18 |
| tlpCoolingDefrostMode This option enables or disables the defrost mode.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.19 |
| tlpCoolingFanSpeed Specifies the actual speed of the evaporator fan. Setting the fan speed
to auto(6) will enable tlpCoolingAutoFanSpeed; however, on most units getting
the fan speed will return t… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.2 |
| tlpCoolingRemoteTemperatureSensor This option enables or disables the remote temperature sensor.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.20 |
| tlpCoolingDehumidifyingMode This option enables or disables the dehumidifying mode.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.21 |
| tlpCoolingFanAlwaysOn This option enables or disables the fan always on.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.22 |
| tlpCoolingQuietMode This option enables or disables the quiet mode.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.23 |
| tlpCoolingHotGasBypass This option enables or disables the hot gas bypass.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.24 |
| tlpCoolingAutoFanSpeed This option enables or disables the auto fan speed.
If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.25 |
| tlpCoolingControlType Specifies which temperature is used as a control point. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.3 |
| tlpCoolingDisplayUnits Specifies whether displays output values in Metric or English formats. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.4 |
| tlpCoolingBeepOnKey Specifies whether a beep is emitted when a key is pressed on the unit's display panel. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.5 |
| tlpCoolingInputContactType The input contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.6 |
| tlpCoolingOutputContactType The output contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.7 |
| tlpCoolingOutputRelaySource The alarm level that causes the output relay to activate. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.8 |
| tlpCoolingOutputRelayDefault Type of contact to make when output relay is activated. If not supported,
this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.5.5.1.1.9 |