tpMldQueryLastMemberInterval

TPLINK-MLDSNOOPING-MIB · .1.3.6.1.4.1.11863.6.43.1.1.3.1.1.15

Object

column r/w Integer32
Enter the Last Listener Query interval time. When the multicast group has no more member ports, 
it will send the Specific Query Message with this interval time to check whether there is another 
member. The interval is ranging from 1 to 5 seconds.

Context

MIB
TPLINK-MLDSNOOPING-MIB
OID
.1.3.6.1.4.1.11863.6.43.1.1.3.1.1.15
Type
column
Access
readwrite
Status
current
Parent
tpMldVlanEntry
Table
tpMldVlanTable
Siblings
15

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-5