tnLldpMessageTxHoldMultiplier

TN-LLDP-MIB · .1.3.6.1.4.1.7483.6.1.2.59.1.1.1.2

Object

column r/w Integer32
The time-to-live value expressed as a multiple of the
tnLldpMessageTxInterval object.  The actual time-to-live value
used in LLDP frames, transmitted on behalf of this LLDP agent,
can be expressed by the following formula: TTL = min(65535,
(tnLldpMessageTxInterval * tnLldpMessageTxHoldMultiplier)) For
example, if the value of tnLldpMessageTxInterval is '30', and
the value of tnLldpMessageTxHoldMultiplier is '4', then the
value '120' is encoded in the TTL field in the LLDP header.
              
The default value for tnLldpMessageTxHoldMultiplier object is 4.
              
The value of this object must be restored from non-volatile
storage after a re-initialization of the management system.

Context

MIB
TN-LLDP-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.59.1.1.1.2
Type
column
Access
readwrite
Status
current
Parent
tnLldpConfigEntry
Table
tnLldpConfigTable
Siblings
8

Syntax

Integer32

Values & Constraints

Object Constraints
range: 2-10

Related Objects

Sibling Objects