tnLagholdTimeDown

TN-LAG-MIB · .1.3.6.1.4.1.7483.6.1.2.15.2.1.17

Object

column r/w 100s of milliseconds Unsigned32
The value of tnLagholdTimeDown specifies the timer in  0.1 second
units which controls the delay between detecting that a LAG is down
(all active ports are down) and reporting it to the higher levels.
The default value for this timer is 0, i.e. the higher levels are
informed directly.
A non zero value may be configured e.g. when active/standby
signalling is used in a 1:1 fashion to avoid that the higher levels
are informed during the small time interval between detecting that
the LAG is down and the time needed to activate the standby system.

Context

MIB
TN-LAG-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.15.2.1.17
Type
column
Access
readwrite
Status
current
Units
100s of milliseconds
Parent
tnLagConfigEntry
Table
tnLagConfigTable
Siblings
19

Syntax

100s of milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-2000

Related Objects

Sibling Objects