tmnxOamPmCfgTwampLtTxFrmsPerDelT

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.10

Object

column r/w frames Unsigned32
The value of tmnxOamPmCfgTwampLtTxFrmsPerDelT specifies the number of
TWAMP-Light frames to send in one MEF-35 'delta_t' (also known as
'Small Time Interval') when computing loss statistics for the
specified session's TWAMP-Light test.
              
The loss parameters used by SROS for TWAMP-Light tests (e.g.
tmnxOamPmCfgTwampLtTxFrmsPerDelT) are modelled after the MEF-35 loss
parameters defined for Synthetic Loss Measurement (SLM) tests.  Hence,
the REFERENCE text for this object is a MEF-35 SLM section.
              
Expressed in milliseconds,
delta_t =
   tmnxOamPmCfgTwampLtTxFrmsPerDelT *
   tmnxOamPmCfgTwampLtInterval.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.10
Type
column
Access
readwrite
Status
current
Units
frames
Parent
tmnxOamPmCfgTwampLtEntry
Table
tmnxOamPmCfgTwampLtTable
Siblings
14

Syntax

frames Unsigned32

Values & Constraints

Object Constraints
range: 1-50

Related Objects

Sibling Objects