tmnxOamPmCfgTwampLtConsecDeltaTs

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.11

Object

column r/w Unsigned32
The value of tmnxOamPmCfgTwampLtConsecDeltaTs specifies the number of
consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals')
which constitute a MEF-35 'Availability Window' when computing loss
statistics for the specified session's TWAMP-Light test.
              
The loss parameters used by SROS for TWAMP-Light tests (e.g.
tmnxOamPmCfgTwampLtConsecDeltaTs) are modelled after the MEF-35 loss
parameters defined for Synthetic Loss Measurement (SLM) tests.  Hence,
the REFERENCE text for this object is a MEF-35 SLM section.
              
The duration of an Availability Window (in milliseconds) is
tmnxOamPmCfgTwampLtTxFrmsPerDelT * tmnxOamPmCfgTwampLtInterval *
tmnxOamPmCfgTwampLtConsecDeltaTs.  An attempt to change the duration of
an Availability Window to more than 100,000 milliseconds will be
rejected.
              
An attempt to change tmnxOamPmCfgTwampLtConsecDeltaTs to a value less
than or equal to tmnxOamPmCfgTwampLtChliThreshold will be rejected.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.11
Type
column
Access
readwrite
Status
current
Parent
tmnxOamPmCfgTwampLtEntry
Table
tmnxOamPmCfgTwampLtTable
Siblings
14

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 2-10

Related Objects

Sibling Objects