tmnxOamPmCfgTwampLtInterval

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.5

Object

column r/w milliseconds Unsigned32
The value of tmnxOamPmCfgTwampLtInterval specifies the elapsed time
between transmission of TWAMP-Test PDUs for the specified session's
TWAMP-Light test.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.5
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
tmnxOamPmCfgTwampLtEntry
Table
tmnxOamPmCfgTwampLtTable
Siblings
14

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 100-100 range: 1000-1000 range: 10000-10000

Related Objects

Sibling Objects