tmnxOamPmCfgLossSlmConsecDeltaTs

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.6.1.8

Object

column r/w Unsigned32
The value of tmnxOamPmCfgLossSlmConsecDeltaTs specifies the number of
consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals')
which constitute a MEF-35 'Availability Window' for the specified
session's SLM test.
              
The duration of an Availability Window (in milliseconds) is
tmnxOamPmCfgLossSlmTxFrmsPerDelT * tmnxOamPmCfgLossSlmInterval *
tmnxOamPmCfgLossSlmConsecDeltaTs.  An attempt to change the duration of
an Availability Window to more than 10,000 milliseconds will be
rejected.
              
An attempt to change tmnxOamPmCfgLossSlmConsecDeltaTs to a value less
than or equal to tmnxOamPmCfgLossSlmChliThreshold will be rejected.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.6.1.8
Type
column
Access
readwrite
Status
current
Parent
tmnxOamPmCfgLossSlmEntry
Table
tmnxOamPmCfgLossSlmTable
Siblings
12

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 2-10

Related Objects

Sibling Objects