vRtrMplsLspPathBfdOperUpWaitTmr

TIMETRA-MPLS-MIB · .1.3.6.1.4.1.6527.3.1.2.6.4.1.77

Object

column seconds Unsigned32
The value of vRtrMplsLspPathBfdOperUpWaitTmr indicates operational
value of the time in seconds the software will wait for the BFD
session to come up.
              
When value of vRtrMplsLspPathBfdEnable to 'true',
vRtrMplsLspPathBfdOperUpWaitTmr  will be set to
vRtrMplsLspPathBfdUpWaitTimer.
              
When value of vRtrMplsLspBfdEnable to 'true',
vRtrMplsLspPathBfdOperUpWaitTmr  will be set to
vRtrMplsLspExtBfdUpWaitTimer.
              
When vRtrMplsLspPathBfdEnable and vRtrMplsLspBfdEnable are set to
'false',  the value of vRtrMplsLspPathBfdOperUpWaitTmr is set to 0.

Context

MIB
TIMETRA-MPLS-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.6.4.1.77
Type
column
Access
readonly
Status
current
Units
seconds
Parent
vRtrMplsLspPathEntry
Table
vRtrMplsLspPathTable
Siblings
78

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 1-60

Related Objects

Sibling Objects