tmnxDot1agCfmMepSlmTWInterval
TIMETRA-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.52.7.4.1.5
Object
column
r/w
Unsigned32
The value of tmnxDot1agCfmMepSlmTWInterval, in conjunction with
tmnxDot1agCfmMepSlmTWIntrvlUnits, specifies the interval between
Synthetic Loss Measurement (SLM) messages sent by the two-way SLM
test. For example, if tmnxDot1agCfmMepSlmTWInterval has the value 90,
and tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)',
the interval between SLM messages is 0.9 seconds.
The tmnxDot1agCfmMepSlmTWInterval and tmnxDot1agCfmMepSlmTWIntrvlUnits
pair provide support for the following intervals:
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 seconds;
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 seconds.
Context
- MIB
- TIMETRA-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.52.7.4.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxDot1agCfmMepSlmTWTestEntry
- Table
- tmnxDot1agCfmMepSlmTWTestTable
- Siblings
- 10
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-90
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxDot1agCfmMepSlmTWTestStatus The value of tmnxDot1agCfmMepSlmTWTestStatus specifies the operational
state of the two-way Synthetic Loss Measurement (SLM) test.
To issue a two-way SLM test the u… | column | TIMETRA-TC-MIBTmnxEnabledDisabled | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.1 |
| tmnxDot1agCfmMepSlmTWTargetMepId The value of tmnxDot1agCfmMepSlmTWTargetMepId specifies the
Maintenance association End Point Identifier (MepId) of another MEP
in the same Maintenance Association that the Synthe… | column | IEEE8021-CFM-MIBDot1agCfmMepIdOrZero | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.10 |
| tmnxDot1agCfmMepSlmTWLstDstMac The value of tmnxDot1agCfmMepSlmTWLstDstMac indicates the
destination MAC addressed used in the most recent two-way SLM Test.
If there is no information about a previous test run,… | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.11 |
| tmnxDot1agCfmMepSlmTWTestId The value of tmnxDot1agCfmMepSlmTWTestId indicates the test identifier
used to initiate the two-way Synthetic Loss Measurement (SLM) test. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.2 |
| tmnxDot1agCfmMepSlmTWMacAddress The value of tmnxDot1agCfmMepSlmTWMacAddress specifies the MAC address
used as a target for the two-way Synthetic Loss Measurement (SLM)
test.
This object MUST be s… | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.3 |
| tmnxDot1agCfmMepSlmTWPriority The value of tmnxDot1agCfmMepSlmTWPriority specifies the priority used
in the generated test frame for the two-way Synthetic Loss Measurement
(SLM) test. | column | Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.4 |
| tmnxDot1agCfmMepSlmTWTimeout The value of tmnxDot1agCfmMepSlmTWTimeout specifies the timeout value,
in seconds, to wait for a Synthetic Loss Measurement (SLM) message to
reply for the two-way SLM test. Upon e… | column | seconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.6 |
| tmnxDot1agCfmMepSlmTWDataSize The value of tmnxDot1agCfmMepSlmTWDataSize specifies the data size, in
bytes, contained in the padding TLV for the two-way Synthetic Loss
Measurement (SLM) test. A value of zero (… | column | bytes Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.7 |
| tmnxDot1agCfmMepSlmTWSendCount The value of tmnxDot1agCfmMepSlmTWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send during the two-way
SLM test. | column | packets Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.8 |
| tmnxDot1agCfmMepSlmTWIntrvlUnits The value of tmnxDot1agCfmMepSlmTWIntrvlUnits, in conjunction with
tmnxDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
Loss Measurement (SLM) messages sent by … | column | Enumeration | .1.3.6.1.4.1.6527.3.1.2.52.7.4.1.9 |