tmnxDot1agCfmMepOWDTTargetMepId

TIMETRA-IEEE8021-CFM-MIB · .1.3.6.1.4.1.6527.3.1.2.52.7.1.1.48

Object

column r/w IEEE8021-CFM-MIBDot1agCfmMepIdOrZero
The value of tmnxDot1agCfmMepOWDTTargetMepId specifies the Maintenance
association End Point Identifier (MepId) of another MEP in the same
Maintenance Association that the One-Way-Delay Test frames will be
sent to.  If the tmnxDot1agCfmMepOWDTTargetMepId is set then a local
lookup for the target MEP destination MAC address will be performed
when the test is started.  Note that a valid target destination MAC
address must be found for proper execution of the one-way-delay-test
if the tmnxDot1agCfmMepOWDTTargetMepId is being used as the input for
the test. The tmnxDot1agCfmMepOWDTTargetMepId cannot be set if the
tmnxDot1agCfmMepOWDTMacAddress is set to a non-zero value.
              
Setting this object will trigger the test frame to be sent. Once the
test is complete, the object will revert to the default value,
indicating that another test is possible.

Context

MIB
TIMETRA-IEEE8021-CFM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.52.7.1.1.48
Type
column
Access
readwrite
Status
current
Parent
tmnxDot1agCfmMepEntry
Table
tmnxDot1agCfmMepTable
Siblings
62

Syntax

IEEE8021-CFM-MIBDot1agCfmMepIdOrZero
Source
IEEE8021-CFM-MIBDot1agCfmMepIdOrZero
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..8191

Related Objects

Sibling Objects