fsMIY1731MepLbmTTL

SUPERMICRO-ECFM-Y1731-MI-MIB · .1.3.6.1.4.1.10876.101.2.7.1.2.4.1.133

Object

column r/w Unsigned32
This object specifies the time-to-live(TTL) value to be used in the 
MPLS outer label header when loopback connectivity verification (ping) 
or diagnostic tests has to be performed to a MEP/MIP in the MPLS-TP 
network.
              
By default TTL value will be 255.
              
If the user sets a particular value, then that TTL will be set and 
carried in LBM packets.
              
When performing loopback connectivity verification (ping) or diagnostic 
tests to a MIP, this object MUST be set to an appropriate TTL value 
needed to reach the MIP.
              
For MIP, this must be configured in conjunction with 
fsMIY1731MepTransmitLbmDestType as mipid(3), fsMIY1731MepLbmIcc,
fsMIY1731MepLbmNodeId, fsMIY1731MepLbmIfNum.
              
For MEP, this must be configured in conjunction with 
fsMIY1731MepTransmitLbmDestType as mepid(1) and 
fsMIY1731MepTransmitLbmDestMepId.

Context

MIB
SUPERMICRO-ECFM-Y1731-MI-MIB
OID
.1.3.6.1.4.1.10876.101.2.7.1.2.4.1.133
Type
column
Access
readwrite
Status
current
Parent
fsMIY1731MepEntry
Table
fsMIY1731MepTable
Siblings
135

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 1-255

Related Objects

Sibling Objects