sub10UnitLclTerminalType
SUB10SYSTEMS-MIB ·
.1.3.6.1.4.1.39003.3.1.1.6
Object
scalar
Sub10TerminalType
Uniquely identifies the local terminal type A or B.
Context
- MIB
- SUB10SYSTEMS-MIB
- OID
.1.3.6.1.4.1.39003.3.1.1.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- sub10UnitLocalStatus
- Siblings
- 17
Syntax
Sub10TerminalType
- Source
- Sub10TerminalType
- Base type
Enumeration
Values & Constraints
Type Values
0 | terminalA |
1 | terminalB |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sub10UnitLclTime The local system time as a display string in the format:-
YYYY-MM-DD,HH:MM:SS e.g. 2014-5-26,13:30:15 | scalar | Sub10DateTime | .1.3.6.1.4.1.39003.3.1.1.1 |
| sub10UnitLclFirmwareLoadedBank Currently loaded bank. The firmware version running in this bank is
defined by sub10UnitLclFirmwareVersion. | scalar | Sub10FirmwareBank | .1.3.6.1.4.1.39003.3.1.1.10 |
| sub10UnitLclFirmwareVersion The firmware version currently running on the local unit.
This is by definition the firmware loaded into the bank
number defined in sub10UnitLclFirmwareLoadedBank. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.11 |
| sub10UnitLclIpAddress The IP address of the local ethernet interface. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.12 |
| sub10UnitLclMWUTemperature The modem temperature on the local unit in degrees celsius. | scalar | Integer32 | .1.3.6.1.4.1.39003.3.1.1.13 |
| sub10UnitLclNTPSyncStatus The indication that the systems clock is synchronised with the
NTP server. | scalar | Sub10NTPSyncStatus | .1.3.6.1.4.1.39003.3.1.1.14 |
| sub10UnitLclAlarmStateTable The table listing the each active alarm the local unit.
An active alarm is where the alarm state is 'raised' at the
specific severity level.
The entries in the table co… | table | - | .1.3.6.1.4.1.39003.3.1.1.15 |
| sub10UnitLclRadioDataRate The maximum data rate of the Airside interface. This has the same
value as sub10RadioLclDataRate. | scalar | Sub10RadioDataRate | .1.3.6.1.4.1.39003.3.1.1.16 |
| sub10UnitLclMWUType The local MWU type | scalar | Sub10MWUType | .1.3.6.1.4.1.39003.3.1.1.17 |
| sub10UnitLclFPGAVersion The FPGA Version. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.18 |
| sub10UnitLclUnitType Uniquely identifies the local unit product type | scalar | Sub10UnitType | .1.3.6.1.4.1.39003.3.1.1.2 |
| sub10UnitLclDescription The description of the local unit.
This is synonymous with MIB-II sysDescr. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.39003.3.1.1.3 |
| sub10UnitLclHWSerialNumber The hardware serial number of the Local Unit.
This also identifies whether the unit is a V-band or E-band product.
See sub10UnitLclMWUType. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.4 |
| sub10UnitLclTerminalName The administratively assigned name for the unit.
This is synonymous with MIB-II sysName and can be
administratively set via either sysName or sub10UnitMgmtTerminalName. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.5 |
| sub10UnitLclLinkName The administratively assigned name for the radio link between
the local and remote units. This generally identifies geographically
the two ends or a radio link within a site or lo… | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.7 |
| sub10UnitLclLinkId The administratively assigned identifier for the radio link between
the local and remote units. The LinkId must be the same value on
both local and remote units. | scalar | OctetString | .1.3.6.1.4.1.39003.3.1.1.8 |
| sub10UnitLclSiteName The administratively assigned physical location of the local unit. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.39003.3.1.1.9 |