psSoftwareVersion
SCTE-HMS-PS-MIB ·
.1.3.6.1.4.1.5591.1.4.2.1.3
Object
column
mandatory
OctetString
The content of this field is vendor specific. The intent is to provide a text representation of the power supply or generator system software version. Any printable ASCII characters can be included in this field. NULL (0x00) characters are non-printable and are used to fill any unused locations following the text data
Context
- MIB
- SCTE-HMS-PS-MIB
- OID
.1.3.6.1.4.1.5591.1.4.2.1.3- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- psDeviceEntry
- Table
- psDeviceTable
- Siblings
- 34
Syntax
OctetString
Values & Constraints
Object Constraints
range: 8-8
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| psDeviceAddress mandatory Index into the psDeviceTable.Address of this device on the RS-485 path | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.1 |
| psFloatCurrentSupport mandatory Bit Map that defines if float current is measured in this installation.
Bit set means this particular string supports this measurement.
Bits Addresses
0 Not used
1 … | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.10 |
| psOutputVoltageSupport mandatory Defines if power supply supports monitoring of output voltage
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installat… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.11 |
| psInputVoltageSupport mandatory Defines if power supply supports monitoring of input or line voltage
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported - value in… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.12 |
| psPowerSupplyTest mandatory Defines if power supply supports the remote test feature:
1 = Function not supported.
2 - Function is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.13 |
| psMajorAlarmSupport mandatory Defines if the power supply supports the major alarm indicator:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this install… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.14 |
| psMinorAlarmSupport mandatory Defines if the power supply supports the minor alarm indicator:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this install… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.15 |
| psTamperSupport mandatory Defines if the enclosure door switch is installed in this location:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this ins… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.16 |
| psBatteryVoltageSupport mandatory Defines the if batteries or string voltage are available:
1 = No battery voltage monitoring is available.
2 = Only full string battery voltage is available.
3 = Both individual ba… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.17 |
| psOutputPowerSupport mandatory Defines if the output power measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.18 |
| psOutputFrequencySupport mandatory Defines if the output frequency measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.19 |
| psProtocolVersion mandatory Version of the SCTE HMS protocol implemented in the monitored
equipment. The 'Protocol Version' implementation will comply
with the defined protocol in the SCTE 25-3 (formerly H… | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.2 |
| psInputCurrentSupport mandatory Defines if the input current measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.20 |
| psInputPowerSupport mandatory Defines if the input power measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.21 |
| psOutputVoltage mandatory Power supply output voltage in 1/100 Volts units.
This RMS value is common for all outputs in a multiple output system.
This item requires an entry in the properties MIB | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.22 |
| psInputVoltage optional Scaled representation of input 'line' or 'grid' voltage. This is an
RMS value in 1/100 Volts units. This item requires an entry in the
properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.23 |
| psInverterStatus optional Status of power supply inverter. Enumerated value indicates current
status of inverter.
1 = OFF,
2 = ON: AC Line Fail,
3 = ON: Local Test Cycle,
4 = ON: Remote test initiated
5… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.24 |
| psMajorAlarm optional Service has been dropped or a service interruption is imminent.
Indicates that an immediate truck roll is appropriate.
Specific alarms and alarm nomenclature varies between vend… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.25 |
| psMinorAlarm optional A non-service effecting condition has occurred and should
be monitored. Specific alarms and alarm nomenclature varies
between vendors. Vendors should disclose all conditions tha… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.26 |
| psTamper optional Indicates status of enclosure door. This notification is
NOT included in the 'Major' or 'Minor' alarm fields.
Individual users / installations must determine if a door
open s… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.27 |
| psTotalStringVoltage optional Scaled representation of the full battery string in 1/100 Volts units.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.28 |
| psEquipmentControl optional Equipment control
1 = Discontinue inverter operation,
2 = Begin inverter operation | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.29 |
| psPowerOut optional Representation of power supply output power in 1 W.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.30 |
| psFrequencyOut optional Scaled representation of the power supply output frequency in 1/100 Hz.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.31 |
| psRMSCurrentIn optional Scaled representation of the power supply RMS input current in 1/100 A.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.32 |
| psPowerIn optional Representation of the power supply input power in 1 W.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.33 |
| psInputVoltagePresence optional Digital value indicating that line voltage is present and within
tolerance or not.
1 = lost
2 = ok.
This item requires entries in the discrete properties MIB. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.34 |
| psFrequencyIn mandatory Operational frequency for input voltage | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.35 |
| psDeviceId mandatory The content of this field is vendor specific. The intent is to provide
manufacturer and/or product specific ASCII text information that will
propagate to the manager's console v… | column | OctetString | .1.3.6.1.4.1.5591.1.4.2.1.4 |
| psBatteries mandatory Current number of batteries per battery string. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.5 |
| psBatteryStrings mandatory Current number of battery strings. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.6 |
| psTempSensors mandatory Number of Battery temperature sensors. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.7 |
| psOutputs mandatory Number of power supply outputs. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.8 |
| psBatteryCurrentSupport mandatory Bit Map that defines if battery current is measured in this installation.
Bit set means this particular string supports this measurement.
Bits Addresses
0 Not used
1 … | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.9 |