psMinorAlarm
SCTE-HMS-PS-MIB ·
.1.3.6.1.4.1.5591.1.4.2.1.26
Object
column
optional
Enumeration
A non-service effecting condition has occurred and should
be monitored. Specific alarms and alarm nomenclature varies
between vendors. Vendors should disclose all conditions that
contribute to this alarm in appropriate product literature.
1 = OK,
2 = ALARM
This item requires entries in the discrete properties MIB.
Context
- MIB
- SCTE-HMS-PS-MIB
- OID
.1.3.6.1.4.1.5591.1.4.2.1.26- Type
- column
- Access
- readonly
- Status
- optional
- Parent
- psDeviceEntry
- Table
- psDeviceTable
- Siblings
- 34
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | noAlarm |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| psDeviceAddress mandatory Index into the psDeviceTable.Address of this device on the RS-485 path | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.1 |
| psFloatCurrentSupport mandatory Bit Map that defines if float current is measured in this installation.
Bit set means this particular string supports this measurement.
Bits Addresses
0 Not used
1 … | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.10 |
| psOutputVoltageSupport mandatory Defines if power supply supports monitoring of output voltage
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installat… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.11 |
| psInputVoltageSupport mandatory Defines if power supply supports monitoring of input or line voltage
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported - value in… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.12 |
| psPowerSupplyTest mandatory Defines if power supply supports the remote test feature:
1 = Function not supported.
2 - Function is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.13 |
| psMajorAlarmSupport mandatory Defines if the power supply supports the major alarm indicator:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this install… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.14 |
| psMinorAlarmSupport mandatory Defines if the power supply supports the minor alarm indicator:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this install… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.15 |
| psTamperSupport mandatory Defines if the enclosure door switch is installed in this location:
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this ins… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.16 |
| psBatteryVoltageSupport mandatory Defines the if batteries or string voltage are available:
1 = No battery voltage monitoring is available.
2 = Only full string battery voltage is available.
3 = Both individual ba… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.17 |
| psOutputPowerSupport mandatory Defines if the output power measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.18 |
| psOutputFrequencySupport mandatory Defines if the output frequency measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.19 |
| psProtocolVersion mandatory Version of the SCTE HMS protocol implemented in the monitored
equipment. The 'Protocol Version' implementation will comply
with the defined protocol in the SCTE 25-3 (formerly H… | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.2 |
| psInputCurrentSupport mandatory Defines if the input current measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.20 |
| psInputPowerSupport mandatory Defines if the input power measurement is supported
1 = No support. Discard associated value in Get_Power_Supply_Data response.
2 = Field is supported in this installation. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.21 |
| psOutputVoltage mandatory Power supply output voltage in 1/100 Volts units.
This RMS value is common for all outputs in a multiple output system.
This item requires an entry in the properties MIB | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.22 |
| psInputVoltage optional Scaled representation of input 'line' or 'grid' voltage. This is an
RMS value in 1/100 Volts units. This item requires an entry in the
properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.23 |
| psInverterStatus optional Status of power supply inverter. Enumerated value indicates current
status of inverter.
1 = OFF,
2 = ON: AC Line Fail,
3 = ON: Local Test Cycle,
4 = ON: Remote test initiated
5… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.24 |
| psMajorAlarm optional Service has been dropped or a service interruption is imminent.
Indicates that an immediate truck roll is appropriate.
Specific alarms and alarm nomenclature varies between vend… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.25 |
| psTamper optional Indicates status of enclosure door. This notification is
NOT included in the 'Major' or 'Minor' alarm fields.
Individual users / installations must determine if a door
open s… | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.27 |
| psTotalStringVoltage optional Scaled representation of the full battery string in 1/100 Volts units.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.28 |
| psEquipmentControl optional Equipment control
1 = Discontinue inverter operation,
2 = Begin inverter operation | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.29 |
| psSoftwareVersion mandatory The content of this field is vendor specific. The intent is to provide
a text representation of the power supply or generator system software
version. Any printable ASCII charact… | column | OctetString | .1.3.6.1.4.1.5591.1.4.2.1.3 |
| psPowerOut optional Representation of power supply output power in 1 W.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.30 |
| psFrequencyOut optional Scaled representation of the power supply output frequency in 1/100 Hz.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.31 |
| psRMSCurrentIn optional Scaled representation of the power supply RMS input current in 1/100 A.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.32 |
| psPowerIn optional Representation of the power supply input power in 1 W.
This item requires an entry in the properties MIB. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.33 |
| psInputVoltagePresence optional Digital value indicating that line voltage is present and within
tolerance or not.
1 = lost
2 = ok.
This item requires entries in the discrete properties MIB. | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.34 |
| psFrequencyIn mandatory Operational frequency for input voltage | column | Enumeration | .1.3.6.1.4.1.5591.1.4.2.1.35 |
| psDeviceId mandatory The content of this field is vendor specific. The intent is to provide
manufacturer and/or product specific ASCII text information that will
propagate to the manager's console v… | column | OctetString | .1.3.6.1.4.1.5591.1.4.2.1.4 |
| psBatteries mandatory Current number of batteries per battery string. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.5 |
| psBatteryStrings mandatory Current number of battery strings. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.6 |
| psTempSensors mandatory Number of Battery temperature sensors. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.7 |
| psOutputs mandatory Number of power supply outputs. | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.8 |
| psBatteryCurrentSupport mandatory Bit Map that defines if battery current is measured in this installation.
Bit set means this particular string supports this measurement.
Bits Addresses
0 Not used
1 … | column | Integer32 | .1.3.6.1.4.1.5591.1.4.2.1.9 |