genOil
SCTE-HMS-GEN-MIB ·
.1.3.6.1.4.1.5591.1.6.2.1.26
Object
column
optional
Enumeration
Indicates if the engine's oil is adequate for safe operation.
Alarm is reset when the condition returns to normal.
This item requires entries in the discrete property table.
Context
- MIB
- SCTE-HMS-GEN-MIB
- OID
.1.3.6.1.4.1.5591.1.6.2.1.26- Type
- column
- Access
- readonly
- Status
- optional
- Parent
- genDeviceEntry
- Table
- genDeviceTable
- Siblings
- 28
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | noAlarm |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| genDeviceAddress mandatory Index into the psDeviceTable.
Address of Generator on the RS-485 Path | column | Integer32 | .1.3.6.1.4.1.5591.1.6.2.1.1 |
| genFuelOption mandatory Defines if low fuel detection is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.10 |
| genVBatIgnitionOption mandatory Defines if engine ignition battery voltage is monitored. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.11 |
| genTempOption mandatory Defines if engine enclosure temperature is monitored. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.12 |
| genGeneratorStatus mandatory Defines the current state of generator operation.
1 = Off
2 = Running(test)
3 = Running
4 = Fail (A condition preventing the generator
from functioning)
… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.13 |
| genGasHazard mandatory The concentration of hydrocarbon fuel in the
generator enclosure has exceeded safe limits.
Generator operation is suspended. The alarm
is cleared when the sensor is reset via t… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.14 |
| genWaterIntrusion mandatory Water level within the generator or fuel enclosure
has exceeded safe limits for generator operation.
Generator operation is suspended while this alarm
is active. The alarm is res… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.15 |
| genPadShear mandatory Indicates that the generator or fuel enclosure
has shifted from its mounting position. Generator
operation is suspended. The alarm is reset when
the unit its returned to its orig… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.16 |
| genEnclosureDoor mandatory Indicates current status of the generator
and/or auxiliary fuel enclosure door.
This item requires entries in the discrete property table. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.17 |
| genCharger mandatory Indicates if the ignition battery charger is operating.
This item requires entries in the discrete property table. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.18 |
| genFuel mandatory Indicates if the engine's fuel supply is sufficient
for extended operation. Alarm is reset when fuel is
replenished.
This item requires entries in the discrete prop… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.19 |
| genProtocolVersion mandatory Version of the SCTE HMS protocol implemented in the monitored
equipment. The 'Protocol Version' implementation will comply
with the defined protocol in the SCTE 25-3 (formerly H… | column | Integer32 | .1.3.6.1.4.1.5591.1.6.2.1.2 |
| genVBatIgnition mandatory Scaled representation of the generator's
ignition battery in 1/100 Volts.
This item requires an entry in the property table. | column | Integer32 | .1.3.6.1.4.1.5591.1.6.2.1.20 |
| genEnclosureTemperature mandatory Temperature inside generator's enclosure in degrees C.
This item requires an entry in the property table. | column | Integer32 | .1.3.6.1.4.1.5591.1.6.2.1.21 |
| genEquipmentControl optional When written, the appropriate corresponding command action
is sent to the generator.
1 = End generator test
2 = Start generator test
3 = Reset latched generator ala… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.22 |
| genOilOption mandatory Defines if oil pressure is monitored. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.23 |
| genMinorAlarmSupport mandatory Defines if the minor alarm indicator is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.24 |
| genMajorAlarmSupport mandatory Defines if the major alarm indicator is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.25 |
| genMinorAlarm optional Indicates if the generator is indicating a minor alarm.
The generator requires attention, but does not require an immediate
visit to the generator.
This item requir… | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.27 |
| genMajorAlarm optional Indicates if the generator is indicating a major alarm.
The generator requires immediate attention, and should be visited
immediately to remedy the situation.
This … | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.28 |
| genVendorOID optional This object provides a means for a vendor to
point to a vendor specific extension of this MIB. | column | ObjectIdentifier | .1.3.6.1.4.1.5591.1.6.2.1.29 |
| genSoftwareVersion mandatory The contents of this field are vendor specific. The intent
is to provide a text representation of the power supply or
generator system software version. Any printable ASCII
charac… | column | OctetString | .1.3.6.1.4.1.5591.1.6.2.1.3 |
| genDeviceId mandatory The content of this field is vendor specific. The intent is
to provide manufacturer and/or product specific ASCII text
information that will propagate to the manager's console
ve… | column | OctetString | .1.3.6.1.4.1.5591.1.6.2.1.4 |
| genGasHazardOption mandatory Defines if gas hazard sensor is installed. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.5 |
| genWaterIntrusionOption mandatory Defines if water intrusion sensor is installed. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.6 |
| genPadShearOption mandatory Defines if pad shear sensor is installed. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.7 |
| genDoorOption mandatory Defines if separate generator door is installed. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.8 |
| genChargerOption mandatory Defines if charger fail signal is supported. | column | Enumeration | .1.3.6.1.4.1.5591.1.6.2.1.9 |