sysCClkSrcMode

RAD-MIB · .1.3.6.1.4.1.164.3.3.1.6.1.1.3

Object

column r/w Enumeration
This entry indicates the source the nodal timing is 
locked to.
none     - is an invalid option for Master clock.
internal - is an invalid option for Fallback clock .
station  - is an invalid option for a stand-alone unit. 
lbt      - loop-back timing
	   ntr      - Network Time Reference 
	   adaptive - clock locking is achieved by altering the clock 
	              according to the data load
	   system   - irrelevant when sysCClkCnfgIdx refers to System Clock.
	   sSubSystem - SONET/SDH Sub System.   
	   recovered  - clock recovery.   
notApplicable - for ML source of Kmux or ML Timing 
                combinations when Master/Fallback clock are
                not applicable.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.3.1.6.1.1.3
Type
column
Access
readwrite
Status
current
Parent
sysCClkSrcEntry
Table
sysCClkSrcTable
Siblings
11

Syntax

Enumeration

Values & Constraints

Object Constraints
range: 0-30

Related Objects

Sibling Objects