prtParamSdBerThreshold

RAD-MIB · .1.3.6.1.4.1.164.6.2.15.5.1.1.28

Object

column r/w Unsigned32
The Signal Degrade Bit Error Rate Threshold.
The negated value of this number is used as the exponent of
10 for computing the threshold value for the Bit Error Rate (BER).
For example, a value of 5 indicates a BER threshold of 10^-5.
              
For disabling the signal degradation, the value will be: 0

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.6.2.15.5.1.1.28
Type
column
Access
readwrite
Status
current
Parent
prtParamEntry
Table
prtParamTable
Siblings
27

Syntax

Unsigned32

Values & Constraints