modmSaConfigLoopback
RAD-MIB ·
.1.3.6.1.4.1.164.3.4.1.1.1.1.2
Object
column
r/w
Enumeration
The possible loopbacks. It is not possible to have a remPortLoop(4) in both, Central and Remote units simultaneously.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.4.1.1.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- modmSaConfigEntry
- Table
- modmSaConfigTable
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| modmSaConfigMode The mode indicates if the configuration parameters refer
the Central or the Remote Modem.
For AMC 102 the remote means regenerator.
There can be some regenerators connecting one… | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.1 |
| modmSaConfigRemote This parameter enables or disables automatic configuration
of the remote moden in Proxy mode. | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.10 |
| modmSaConfigPsType The type of PS. | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.11 |
| modmSaConfigWorkMode The work mode indicates if devices work in transparent mode or termination mode. | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.12 |
| modmSaConfigAlrClearOnCmd Setting this attribute to on, clears all the events,
both from the active alarms list and from the alarms buffer.
Upon completion, the value will automatically change to
off(2). | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.3 |
| modmSaConfigAlrClearAllCmd Setting this attribute to on, clears all the alarms of the
alarm buffer and active alarms list. Upon completion, the
value will automatically change to off(2). | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.4 |
| modmSaConfigTestClearCmd Setting this attribute to on, clears all the user-initiated
tests and loopbacks. The variable modmSaConfigLoopback should
automatically change to noLoopback. Upon completion, the … | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.5 |
| modmSaConfigClkMaster Modem configured as Central:
External - Locked to the clock signal provided by the user's
equipment by user's port.
Internal - Internal oscillator.
Station … | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.6 |
| modmSaConfigResetStatistics In the on state all statistics counters (including E1
counters) are zeroed. Upon completion, the value will
automatically change to off(2).
Modems that do not support statistic… | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.7 |
| modmSaConfigActiveTs This object will be RO for the Remote modem.
This is the number of active HDSL Time Slots, that
determines user's data rate.
Valid values: 1..maximum supported by the specific mo… | column | Integer32 | .1.3.6.1.4.1.164.3.4.1.1.1.1.8 |
| modmSaConfigReset Reset of modem.
hw - HW Reset. The configured values will not change.
hwAndConfig - HW Reset and initializing the default values.
notApplicable - for modems with no Reset support.… | column | Enumeration | .1.3.6.1.4.1.164.3.4.1.1.1.1.9 |