mdlDsAnswerSig
RAD-MIB ·
.1.3.6.1.4.1.164.3.6.2.4.1.8
Object
column
r/w
OctetString
This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Near PBX to the Far PBX,
taht a call is present now on the line.
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Applicable only for KVF.6 cards.
It represents 4 parameters, by an Octet:
( Bit 7 = MSB, Bit 0 = LSB )
D Bit - bits 6,7 of the MSB nibble,
C Bit - bits 4,5 of the MSB nibble,
B Bit - bits 2,3 of the LSB nibble,
A Bit - bits 0,1 of the LSB nibble.
For each of A,B,C,D Bits:
00 = 0,
01 = 1,
10 = reserved,
11 = x.
For A,B Bits - only one of them can be 'x' (not both at the same time).
For C,D Bits - 'x' won't be in use.
When the object is not applicable, a 0 Octet will be sent.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.6.2.4.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- mdlDisconnectSupervisionEntry
- Table
- mdlDisconnectSupervisionTable
- Siblings
- 16
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mdlDsConfigIdx This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
Write operation for the table entries is allowed only to
Config=2… | column | Integer32 | .1.3.6.1.4.1.164.3.6.2.4.1.1 |
| mdlDsFbtLowFreq First frequency in Fast Busy Tone (Fbt) combination (Hz).
Valid values: 0..4000,4095. 4095 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disa… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.10 |
| mdlDsFbtHighFreq Second frequency in Fast Busy Tone (Fbt) combination (Hz).
Valid values: 0..4000,4095. 4095 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from dis… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.11 |
| mdlDsFbtTimeOn1 This object defines the Time On 1 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect Supervi… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.12 |
| mdlDsFbtTimeOff1 This object defines the Time Off 1 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.13 |
| mdlDsFbtTimeOn2 This object defines the Time On 2 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.14 |
| mdlDsFbtTimeOff2 This object defines the Time Off 2 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.15 |
| mdlDsFbtLowFreqLevel First frequency level for Fast Busy Tone (Fbt) in dBm units.
Valid values: -32..31.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'To… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.16 |
| mdlDsFbtHighFreqLevel Second frequency level for Fast Busy Tone (Fbt) in dBm units.
Valid values: -32..31.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'T… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.17 |
| mdlDsSlotIdx This object indicates a unique number of the slot position
in which the module is inserted. | column | Enumeration | .1.3.6.1.4.1.164.3.6.2.4.1.2 |
| mdlDs This object defines which terms will cause disconnection of call.
disable = the Disconnect Supervision feature is disabled. In this case,
all other objects of this table are irrel… | column | Enumeration | .1.3.6.1.4.1.164.3.6.2.4.1.3 |
| mdlDsUserLoc User located in local or remote station.
Local station will disconnect the call actually if needed.
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Sh… | column | Enumeration | .1.3.6.1.4.1.164.3.6.2.4.1.4 |
| mdlDsMode This object defines the action, which will be done after remote disconnect occurred.
This object is relevant only when mdlDsUserLoc = local(3).
Applicable only if Disconnect Super… | column | Enumeration | .1.3.6.1.4.1.164.3.6.2.4.1.5 |
| mdlDsSilence This object defines the silence period needed for an indication (seconds).
Applicable only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Silence', … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.6.2.4.1.6 |
| mdlDsClrFwSig This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Near PBX to the Far PBX,
that it wants to disconnect the call.
Applicable… | column | OctetString | .1.3.6.1.4.1.164.3.6.2.4.1.7 |
| mdlDsClrBwSig This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Far PBX to the Near PBX,
that the call was disconnected (on the Far si… | column | OctetString | .1.3.6.1.4.1.164.3.6.2.4.1.9 |