agnPtpClkPrtPriority2

RAD-Clock-MIB · .1.3.6.1.4.1.164.6.2.52.4.1.1.34

Object

column r/w Unsigned32
This object is relevant when agnPtpClkType=g82751Master(6).
It is used in the execution of the best master clock algorithm. 
Lower values take precedence. It provides finer grained ordering 
among otherwise equivalent clocks.

Context

MIB
RAD-Clock-MIB
OID
.1.3.6.1.4.1.164.6.2.52.4.1.1.34
Type
column
Access
readwrite
Status
current
Parent
agnPtpClkEntry
Table
agnPtpClkTable
Siblings
33

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-255

Related Objects

Sibling Objects