agnPtpClkProfileType
RAD-Clock-MIB ·
.1.3.6.1.4.1.164.6.2.52.4.1.1.33
Object
column
r/w
Enumeration
The object set the profile type.
Context
- MIB
- RAD-Clock-MIB
- OID
.1.3.6.1.4.1.164.6.2.52.4.1.1.33- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- agnPtpClkEntry
- Table
- agnPtpClkTable
- Siblings
- 33
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | telecomEndToEnd |
3 | telecomPeerToPeer |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| agnPtpClkType This object uniquely represents the PTP Clock Type(PTP1588 or,
G.8275.1, or G.8275.2, Master or Slave, same as agnClkSrcPortSrcIdx
(from agnClkSrcPortTable). | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.1 |
| agnPtpClkPbit This object indicates the Priority bit value (range is 0..7)
of the PTP frame. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.10 |
| agnPtpClkNumOfIntervals The number of previous 15-minutes intervals for which data was collected. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.11 |
| agnPtpClkCurr15TimeElapsed This object indicates the number of seconds that have elapsed
since the beginning of the current error-measurement period
(range is 0..899). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.12 |
| agnPtpClkCurr15TxSyncPackets The counter associated with the number of Transmitted Sync Packets,
encountered by this PTP clock in the current 15 minute interval. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.13 |
| agnPtpClkCurr15RxSyncPackets The counter associated with the number of Received Sync Packets,
encountered by this PTP clock in the current 15 minute interval. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.14 |
| agnPtpClkCurr15RxFollowupPackets The counter associated with the number of Received Followup Packets,
encountered by this PTP clock in the current 15 minute interval. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.15 |
| agnPtpClkState This object indicates the PTP clock state.
Failuer - The clock state is - Failuer
OK - The clock state is - OK
Lld - Lower Layer Down | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.16 |
| agnPtpClkIndicatedQl This object indicates the PTP clock QL that transmit to the CSM. | column | ClockQlList | .1.3.6.1.4.1.164.6.2.52.4.1.1.17 |
| agnPtpClkClockIdentity deprecated The identity of the clock. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.18 |
| agnPtpClkRecoveryMode This object defines the revertive mode. | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.19 |
| agnPtpClkId This object uniquely represents the PTP Clock ID,
same as agnClkSrcPortIdx (from agnClkSrcPortTable). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.2 |
| agnPtpClkWtr Wait to Restore (WTR) time in sec. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.20 |
| agnPtpClkDomain For PTP Slave - The domain number in the send header message,
use to verify that the domain number in the receive message is the same,
otherwise the package will be discard.
For P… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.21 |
| agnPtpClkIpAddress The IP Address of the Slave, used in NE with more then one Slaves. | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.164.6.2.52.4.1.1.22 |
| agnPtpClkActiveMaster This object indicates the current active master per slave(recovered). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.23 |
| agnPtpClkRecoveryModeSelect This object enables to combine between the 1588 and the syncE clock recovery.
The actual frequency used from clock selector output to 1588 does not
need to be configured.
Default:… | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.24 |
| agnPtpClkPortMaxSlaves This object sets the maximum number of registered slaves per Master. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.25 |
| agnPtpClkPortTxClockDomain This object set the community domain. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.26 |
| agnPtpClkMasterStatus This object indicates the Master Status. | column | Bits | .1.3.6.1.4.1.164.6.2.52.4.1.1.27 |
| agnPtpClkIpAddressType This object indicates the Type of the Address for agnPtpClkIpAddress. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.164.6.2.52.4.1.1.28 |
| agnPtpClkNetMetricsClearCounters Setting this object to masterToSlave(2) or slaveToMaster(3), will enforce a clear
operation for agnPtpClkNetMetricsCurrentTable (Master to Slave or Slave to Master) Counters. Upon… | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.29 |
| agnPtpClkSrcPrtClkId This object indicates the Source Port Clock ID,
within the Source Port Identity. | column | OctetString | .1.3.6.1.4.1.164.6.2.52.4.1.1.3 |
| agnPtpClkIdentity The identity of the clock. | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.164.6.2.52.4.1.1.30 |
| agnPtpClkAsymmetryCorrection deprecated The object use to compensate between TX and RX packet delay. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.31 |
| agnPtpClkJointFrequencyTime The object set the 1PPS algorithm to:
enable - recovered frequency and time
disable - recovered time only. | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.32 |
| agnPtpClkPrtPriority2 This object is relevant when agnPtpClkType=g82751Master(6).
It is used in the execution of the best master clock algorithm.
Lower values take precedence. It provides finer graine… | column | Unsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.34 |
| agnPtpClkSrcPrtNumber This object indicates the Source Port Number,
within the Source Port Identity. | column | OctetString | .1.3.6.1.4.1.164.6.2.52.4.1.1.4 |
| agnPtpClkSyncRate This object indicates the Sync Rate of the packet,
which is transmitted from the master clock towards the slave clock. | column | Enumeration | .1.3.6.1.4.1.164.6.2.52.4.1.1.5 |
| agnPtpClkQualityLogVar This object indicates the stability of the master clock. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.6 |
| agnPtpClkAddrType This object indicates the Type of the Address, used by this PTP clock. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.164.6.2.52.4.1.1.7 |
| agnPtpClkMcastAddr This object indicates the Multicast Address, according to agnPtpClkAddrType. | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.164.6.2.52.4.1.1.8 |
| agnPtpClkTos This object indicates the TOS value (range is 0..255) or the DSCP value
(range is 0..64) of the PTP frame.
255 = not applicable | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.52.4.1.1.9 |