upsHighPrecBatteryCurrentTable
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.2.3.9
Object
table
mandatory
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.2.3.9- Type
- table
- Status
- mandatory
- Parent
- upsHighPrecBattery
- Siblings
- 16
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsHighPrecBatteryCapacity mandatory The remaining battery capacity expressed in
tenths of percent of full capacity. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.3.1 |
| upsHighPrecBatteryPacks | node | - | .1.3.6.1.4.1.318.1.1.1.2.3.10 |
| upsHighPrecBatteryHealth mandatory The battery health.
Bit 0 Battery life okay
Bit 1 Battery life near end, order battery cartridge
Bit 2 Battery life exceeded, replace battery cartridge
Bit 3 Battery life near end… | scalar | OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.11 |
| upsHighPrecActivePower mandatory Active Power of Battery in tenths of kW | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.12 |
| upsHighPrecExtdBatteryTemperature mandatory The current internal UPS temperature expressed in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.13 |
| upsHighPrecMaximumModuleTemperature mandatory The current maximum temperature across all battery modules in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.14 |
| upsHighPrecMinimumModuleTemperature mandatory The current minimum temperature across all battery modules in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.15 |
| upsHighPrecMaximumCellVoltage mandatory The current maximum cell voltage in mVDC across all batteries. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.16 |
| upsHighPrecMinimumCellVoltage mandatory The current minimum cell voltage in mVDC across all batteries. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.17 |
| upsHighPrecBatteryTemperature mandatory The current internal UPS temperature expressed in
tenths of degrees Celsius. Temperatures below zero
read as 0.
Consider using upsHighPrecExtdBatteryTemperature instead… | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.3.2 |
| upsHighPrecBatteryNominalVoltage mandatory The nominal battery voltage in tenths of Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.3 |
| upsHighPrecBatteryActualVoltage mandatory The actual battery bus voltage in tenths of Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.4 |
| upsHighPrecBatteryCurrent mandatory The battery current in tenths of Amps.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.5 |
| upsHighPrecTotalDCCurrent mandatory The total DC current in tenths of Amps. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.6 |
| upsHighPrecBatteryActualVoltageTable mandatory A list of Battery frame table entries. The number of entries
is given by the number of Battery frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.3.7 |
| upsHighPrecTotalDCCurrentTable mandatory A list of Battery Frame table entries. The number of entries
is given by the number of battery frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.3.8 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsHighPrecBatteryCurrentEntry mandatory An entry containing information applicable to a
particular battery frame. | row | - | .1.3.6.1.4.1.318.1.1.1.2.3.9.1 |