upsHighPrecBattery
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.2.3
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.2.3- Type
- node
- Parent
- upsBattery
- Siblings
- 7
- Children
- 17
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsBasicBattery | node | - | .1.3.6.1.4.1.318.1.1.1.2.1 |
| upsAdvBattery | node | - | .1.3.6.1.4.1.318.1.1.1.2.2 |
| upsBatteryNumberOfCabinets mandatory The value indicates the number of battery cabinets in total, internal and external.
If the UPS only has internal batteries, that number should be 1.
If the UPS has external and in… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.4 |
| upsBatteryCabinetTable optional Table of battery cabinets | table | - | .1.3.6.1.4.1.318.1.1.1.2.5 |
| upsBatteryCabStringTable optional Table of battery strings in the complete battery solution | table | - | .1.3.6.1.4.1.318.1.1.1.2.6 |
| upsBatteryCabBlockTable optional Table of battery blocks/modules in the complete battery solution. | table | - | .1.3.6.1.4.1.318.1.1.1.2.7 |
| upsBatteryCabBlockCellTable optional Table of battery cells in a battery block/module in the complete battery solution | table | - | .1.3.6.1.4.1.318.1.1.1.2.8 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsHighPrecBatteryCapacity mandatory The remaining battery capacity expressed in
tenths of percent of full capacity. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.3.1 |
| upsHighPrecBatteryPacks | node | - | .1.3.6.1.4.1.318.1.1.1.2.3.10 |
| upsHighPrecBatteryHealth mandatory The battery health.
Bit 0 Battery life okay
Bit 1 Battery life near end, order battery cartridge
Bit 2 Battery life exceeded, replace battery cartridge
Bit 3 Battery life near end… | scalar | OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.11 |
| upsHighPrecActivePower mandatory Active Power of Battery in tenths of kW | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.12 |
| upsHighPrecExtdBatteryTemperature mandatory The current internal UPS temperature expressed in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.13 |
| upsHighPrecMaximumModuleTemperature mandatory The current maximum temperature across all battery modules in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.14 |
| upsHighPrecMinimumModuleTemperature mandatory The current minimum temperature across all battery modules in
tenths of degrees Celsius. Can be negative. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.15 |
| upsHighPrecMaximumCellVoltage mandatory The current maximum cell voltage in mVDC across all batteries. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.16 |
| upsHighPrecMinimumCellVoltage mandatory The current minimum cell voltage in mVDC across all batteries. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.17 |
| upsHighPrecBatteryTemperature mandatory The current internal UPS temperature expressed in
tenths of degrees Celsius. Temperatures below zero
read as 0.
Consider using upsHighPrecExtdBatteryTemperature instead… | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.3.2 |
| upsHighPrecBatteryNominalVoltage mandatory The nominal battery voltage in tenths of Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.3 |
| upsHighPrecBatteryActualVoltage mandatory The actual battery bus voltage in tenths of Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.4 |
| upsHighPrecBatteryCurrent mandatory The battery current in tenths of Amps.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.5 |
| upsHighPrecTotalDCCurrent mandatory The total DC current in tenths of Amps. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.3.6 |
| upsHighPrecBatteryActualVoltageTable mandatory A list of Battery frame table entries. The number of entries
is given by the number of Battery frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.3.7 |
| upsHighPrecTotalDCCurrentTable mandatory A list of Battery Frame table entries. The number of entries
is given by the number of battery frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.3.8 |
| upsHighPrecBatteryCurrentTable mandatory A list of Battery Frame table entries. The number of entries
is given by the number of battery frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.3.9 |