dm3ConfigRectAlarms
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.7.2.4.1.2
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.7.2.4.1.2- Type
- node
- Parent
- dm3ConfigRectifier
- Siblings
- 1
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dm3ConfigRectThresh | node | - | .1.3.6.1.4.1.318.1.1.7.2.4.1.1 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dm3ConfigRectHighVoltAlarm mandatory For the Rectifier High Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be ac… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.1 |
| dm3ConfigRectFanFailAlarm mandatory For the Rectifier Fan Fail Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activa… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.10 |
| dm3ConfigRectFailAlarm mandatory For the Rectifier Fail Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.11 |
| dm3ConfigRectHwVoltAlarm mandatory For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits,
or a possible measurement fault);
Setting this OID to alarmIgnore (1) results in the alarm c… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.12 |
| dm3ConfigRectLowVoltAlarm mandatory For the Rectifier Low Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be act… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.2 |
| dm3ConfigRectConfigAlarm mandatory This alarm is activated when a new rectifier is detected;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) cau… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.3 |
| dm3ConfigRect1ofNAlarm mandatory This setting indicates the action if ONE rectifier of a N+1 system has failed;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID t… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.4 |
| dm3ConfigRect2ofNAlarm mandatory This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.5 |
| dm3ConfigRectDiagAlarm mandatory For the Rectifier Controller Diagnostics Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.6 |
| dm3ConfigRectImbalanceAlarm mandatory For the Rectifier Imbalance Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activ… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.7 |
| dm3ConfigRectCurrLimitAlarm mandatory For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.8 |
| dm3ConfigRectStandbyAlarm mandatory For the Rectifier Standby Alarm (indicating output DC has been turned off);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to a… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.1.2.9 |