dm3ConfigConvFanFailAlarm
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.7.2.4.2.2.10
Object
scalar
mandatory
r/w
Enumeration
For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.7.2.4.2.2.10- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- dm3ConfigConvAlarms
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | alarmIgnore |
2 | alarmRelay1 |
3 | alarmRelay2 |
4 | alarmRelay3 |
5 | alarmRelay4 |
6 | alarmRelay5 |
7 | alarmRelay6 |
8 | alarmMinor |
9 | alarmMajor |
10 | alarmNofN |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dm3ConfigConvHighVoltAlarm mandatory For the Converter High Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be ac… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.1 |
| dm3ConfigConvFailAlarm mandatory For the Converter Fail Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.11 |
| dm3ConfigConvHwVoltAlarm mandatory For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a
possible measurement fault);
Setting this OID to alarmIgnore (1) results in the alarm condition … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.12 |
| dm3ConfigConvLowVoltAlarm mandatory For the Converter Low Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be act… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.2 |
| dm3ConfigConvConfigAlarm mandatory For the Converter Configuration Alarm (indicating a new converter has been detected);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting thi… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.3 |
| dm3ConfigConv1ofNAlarm mandatory For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Set… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.4 |
| dm3ConfigConv2ofNAlarm mandatory For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed);
Setting this OID to alarmIgnore (1) results in the alarm condition being ign… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.5 |
| dm3ConfigConvDiagAlarm mandatory For the Converter Diagnostics Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be act… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.6 |
| dm3ConfigConvImbalanceAlarm mandatory For the Converter Imbalance Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activ… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.7 |
| dm3ConfigConvCurrLimitAlarm mandatory For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
S… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.8 |
| dm3ConfigConvStandbyAlarm mandatory For the Converter Standby Alarm (indicating the converter is in the Standby state);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.9 |