dm3ConfigConvAlarms
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.7.2.4.2.2
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.7.2.4.2.2- Type
- node
- Parent
- dm3ConfigConverter
- Siblings
- 1
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dm3ConfigConvThresh | node | - | .1.3.6.1.4.1.318.1.1.7.2.4.2.1 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dm3ConfigConvHighVoltAlarm mandatory For the Converter High Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be ac… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.1 |
| dm3ConfigConvFanFailAlarm mandatory For the Converter Fan Fail Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activa… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.10 |
| dm3ConfigConvFailAlarm mandatory For the Converter Fail Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.11 |
| dm3ConfigConvHwVoltAlarm mandatory For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a
possible measurement fault);
Setting this OID to alarmIgnore (1) results in the alarm condition … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.12 |
| dm3ConfigConvLowVoltAlarm mandatory For the Converter Low Voltage Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be act… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.2 |
| dm3ConfigConvConfigAlarm mandatory For the Converter Configuration Alarm (indicating a new converter has been detected);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting thi… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.3 |
| dm3ConfigConv1ofNAlarm mandatory For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Set… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.4 |
| dm3ConfigConv2ofNAlarm mandatory For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed);
Setting this OID to alarmIgnore (1) results in the alarm condition being ign… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.5 |
| dm3ConfigConvDiagAlarm mandatory For the Converter Diagnostics Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be act… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.6 |
| dm3ConfigConvImbalanceAlarm mandatory For the Converter Imbalance Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activ… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.7 |
| dm3ConfigConvCurrLimitAlarm mandatory For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
S… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.8 |
| dm3ConfigConvStandbyAlarm mandatory For the Converter Standby Alarm (indicating the converter is in the Standby state);
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.7.2.4.2.2.9 |