mspCommand

PROTECTION-MIB · .1.3.6.1.4.1.1038.130.10.2.1.11

Object

column r/w MspCommand
Manual or forced commands can be apply to the protection switch.
The forced and manual switch can be refused or cleared by equipment
if a higher priority APS command is received or if the protection chanel
is down.
When this field is set to manual or forced, the mspTraffic field
becomes read-write, and a set can be issued to specifie on which
chanel the command does apply.
Commands: 
	LP (Lockout of Protection) 
	LW (Lockout of Working channel)
	FSW (Forced Switch of a Working channel to protection)
	FSP (Forced Switch of a Protection channel to working) case 1+1
	MSW (Manual Switch of a Working channel to protection)
	MSp (Manual Switch of a Protection channel to working) case 1+1 
	EXER (EXERcise)

Context

MIB
PROTECTION-MIB
OID
.1.3.6.1.4.1.1038.130.10.2.1.11
Type
column
Access
readwrite
Status
current
Parent
mspEntry
Table
mspTable
Siblings
18

Syntax

MspCommand
Source
MspCommand
Base type
Enumeration

Values & Constraints

Type Values
0clear
1lw
2lp
3fsW
4fsP
5msW
6msP
7exer